Network Interface (NI) Modules
Removing and Adding Modules
OmniSwitch 7700/7800 Hardware Users Guide
April 2005
page 5-25
Module Types and Slot Positions
When installing modules in the chassis, consider the following:
•
NI modules may be installed in any slot position from 1 through 8 in OS7700 switches and 1 through
16 in OS7800 switches. All NI modules are interchangeable between OS7700 and OS7800 chassis
types.
•
CMMs may be installed in slots A or B in OS7700 and OS7800 switches.
•
NI modules cannot be installed in CMM slots A or B; likewise, CMMs cannot be installed in any NI
slot position.
•
Due to the differences in their physical dimensions, OS7700 and OS7800 CMMs are not interchange-
able.
More Information on Slot Numbering.
For a diagram showing the chassis layout and slot positions,
refer to
Chapter 2, “Chassis and Power Supplies.”
Removing a Module
To remove an NI or CMM module from the chassis, follow the steps below.
1
First, loosen the module’s two captive screws that secure the module to the chassis. If necessary, use a
flat-blade screwdriver to loosen the screws. Be sure that both captive screws are completely disengaged
from the threaded holes in the chassis before continuing.