efm-oam port propagate-events
Configures whether or not the specified port or range of ports will propagate local event notifications to
the remote peer.
efm-oam port slot/port[-port2] propagate-events {critical-event | dying-gasp} {enable | disable}
Syntax Definitions
slot/port
The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
-port2
Specifies the last port in the range of ports.
critical-event
Configures the notification status for critical events.
dying-gasp
Configures the notification status for dying gasp events.
enable
Enables the notification of critical-event or dying-gasp events to the
peer.
disable
Disables the notification of critical-event or dying-gasp events to the
peer.
Defaults
By default, the notification status for both critical-event and dying-gasp events is set to enabled.
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
•
When the system is set for critical event or a dying-gasp event, the local OAM entity indicates the
event through the OAMPDU flags to its peer OAM entity.
•
In case of port admin down, the OAM IFU-PDU with dying-gasp bit set will be sent to peer as soon as
a failure is detected and transmission will continue till the specific port actually goes down.
•
In case of takeover or reload of the switch, the OAM IFU-PDU with dying-gasp bit set will be sent to
peer as soon as a failure is detected and transmission will continue till the specific device actually goes
down.
•
The information PDUs with dying gasp bit set is transmitted towards peer as soon as link-down is
detected at NI. However, if there is a link flap (i.e link comes again) before the expiry of link-flap
timer, then normal information PDU transmission with dying-gasp bit reset shall resume. This will
cause clearing of alarms or trap on the peer port.
Examples
-> efm-oam port 1/1 propagate-events critical-event enable
-> efm-oam port 1/1 propagate-events critical-event disable
-> efm-oam port 2/1-10 propagate-events dying-gasp enable
-> efm-oam port 2/1-4 propagate-events dying-gasp disable
Summary of Contents for OmniSwitch 6250
Page 140: ...Power over Ethernet PoE Commands page 4 18 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 212: ...Session Management Commands page 6 52 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 270: ...File Management Commands page 7 58 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 280: ...Web Management Commands page 8 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 328: ...SNMP Commands page 10 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 338: ...DNS Commands page 11 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 392: ...Link Aggregation Commands page 12 54 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 440: ...802 1Q Commands page 15 8 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 628: ...Loopback Detection Commands page 17 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 768: ...Ethernet Port Commands page 20 96 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 826: ...VLAN Management Commands page 22 26 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 968: ...Ethernet OAM Commands page 25 56 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1014: ...LINK OAM Commands page 26 46 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1036: ...UDLD Commands page 27 22 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1048: ...Port Mapping Commands page 28 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1256: ...IPv6 Commands page 30 90 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1276: ...RDP Commands page 31 20 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1372: ...RIP Commands page 33 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1702: ...QoS Policy Commands page 39 206 OmniSwitch CLI Reference Guide November 2009...
Page 1718: ...Policy Server Commands page 40 16 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 2018: ...Index Index 6 OmniSwitch 6250 CLI Reference Guide November 2009...