Distributed Spanning Tree Commands
OmniSwitch 6250 CLI Reference Guide
November 2009
page 16-51
bridge auto-vlan-containment
Enables or disables Auto VLAN Containment (AVC). When enabled, AVC prevents a port that has no
VLANs mapped to an Multiple Spanning Tree Instance (MSTI) from becoming the root port for that
instance. Such ports are automatically assigned an infinite path cost value to make them an inferior choice
for root port.
bridge [msti msti_id] auto-vlan-containment {enable | disable}
Syntax Definitions
msti_id
An existing MSTI ID number (0–4094).
enable
Enables automatic VLAN containment.
disable
Disables automatic VLAN containment.
Defaults
By default, automatic VLAN containment is disabled.
Platforms Supported
OmniSwitch 6250
Usage Guidelines
•
The AVC feature is not active for any MSTI until it is globally enabled. To globally enable this feature,
use the
bridge auto-vlan-containment
command but do not specify an
msti_ id
.
•
When AVC is globally enabled, it is active for all MSTIs. To disable AVC for a single instance, use
the
disable
form of this command and specify the
msti_id
for the instance.
•
Use the
enable
form of this command and specify an
msti_id
to enable AVC for an instance that was
previously disabled.
•
An administratively set port path cost takes precedence and prevents AVC configuration of the path
cost. The exception to this is if the port path cost is administratively set to zero, which resets the path
cost to the default value.
•
Note that when AVC is disabled that a port assigned to a VLAN not mapped to a specific instance can
become the root port for that instance and cause a loss of connectivity between other VLANs.
•
AVC does not have any effect on root bridges.
Examples
-> bridge auto-vlan-containment enable
-> bridge auto-vlan-containment disable
-> bridge msti 1 auto-vlan-containment disable
-> bridge msti 1 auto-vlan containment enable
Release History
Release 6.6.1; command was introduced.
Summary of Contents for OmniSwitch 6250
Page 140: ...Power over Ethernet PoE Commands page 4 18 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 212: ...Session Management Commands page 6 52 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 270: ...File Management Commands page 7 58 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 280: ...Web Management Commands page 8 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 328: ...SNMP Commands page 10 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 338: ...DNS Commands page 11 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 392: ...Link Aggregation Commands page 12 54 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 440: ...802 1Q Commands page 15 8 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 628: ...Loopback Detection Commands page 17 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 768: ...Ethernet Port Commands page 20 96 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 826: ...VLAN Management Commands page 22 26 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 968: ...Ethernet OAM Commands page 25 56 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1014: ...LINK OAM Commands page 26 46 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1036: ...UDLD Commands page 27 22 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1048: ...Port Mapping Commands page 28 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1256: ...IPv6 Commands page 30 90 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1276: ...RDP Commands page 31 20 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1372: ...RIP Commands page 33 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 1702: ...QoS Policy Commands page 39 206 OmniSwitch CLI Reference Guide November 2009...
Page 1718: ...Policy Server Commands page 40 16 OmniSwitch 6250 CLI Reference Guide November 2009...
Page 2018: ...Index Index 6 OmniSwitch 6250 CLI Reference Guide November 2009...