IAO LAN and TCP/IP cable installation
Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)
1 - 6 4
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
IAO LAN and TCP/IP cable installation
Description
This section describes how to connect the IAO LAN/TCP-IP (LAN 10BaseT) cable to the
1665 DMX High-Capacity shelf and to the interfacing equipment. Perform this procedure
if this cabling is required.
The 1665 DMX High-Capacity shelf supports an IntraOffice LAN (IAO LAN) interface
for operations data communications to support operations systems such as the Navis
Optical Management System (OMS).
Since the IAO LAN can be provisioned as an extension of the SONET DCC, the IAO
LAN can also be used to join multiple, otherwise separate subnetworks.
All NE-to-NE OI features that are supported over the DCC are also supported over the
IAO LAN.
The IAO LAN/TCP-IP interface cable is available in two configurations (cross-over and
straight-through) and may be connected to either the front or rear of the 1665 DMX High-
Capacity shelf. The following tables provide additional information:
•
Table 1-13, “LAN 10BaseT cable assemblies” (p. 1-67)
•
Table 1-14, “LAN 10BaseT cross-over cable connections” (p. 1-68)
•
Table 1-15, “LAN 10BaseT straight-through cable connections” (p. 1-68)
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
If connecting directly to a PC, use a LAN 10BaseT cross-over cable assembly (see
).
If connecting to a hub, use a LAN 10BaseT straight-through cable assembly (see
).
........................................................................................................................................................................................................................
2
If connecting to the front of the 1665 DMX High-Capacity shelf, connect the cable to the
LAN (RJ45) jack on the SYSCTL circuit pack. See
Figure 1-20, “LAN cable installation
to front of 1665 DMX High-Capacity shelf” (p. 1-65)
.
If connecting to the rear of the 1665 DMX High-Capacity shelf, connect the cable to the
J16 port (IAO LAN) on the 1665 DMX High-Capacity shelf backplane. See
“IAO LAN/TCP-IP cable installation to rear of 1665 DMX High-Capacity shelf”
(p. 1-66)
.
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...