Cleaning/inspecting optical connectors
Fiber cleaning
B - 1 0
365-372-304R7.1
Issue 1, November 2007
Figure B-3
Acceptability Criteria for Fiber Cleaning
........................................................................................................................................................................................................................
3
After the connector has been verified to be cleaned, it should be immediately inserted into
the adapter buildout of the optical component. This will assure maximum cleanliness and
effectiveness of the connector.
........................................................................................................................................................................................................................
4
If the cleaned connector cannot be immediately connected to a corresponding adapter, the
connector ferrule must be protected with a connector dust cap. Before placing the cap on
the ferrule, make sure the cap is clean. This can be accomplished by inserting a CLETOP
stick cleaner (swab) of the same inside diameter as the cap (either 2.5 or 1.25 mm) and
rotate the stick 360 degrees three (3) times. Following this procedure, carefully place the
cap over the ferrule. When the cleaned connector is ready for assembly, it should be re-
inspected for cleanliness prior to connection.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Fiber adapters or circuit pack connectors
During testing and/or trouble shooting activities it may be necessary to clean the optical
buildout adapter or the circuit pack connector. The following procedure is recommended.
66u
m
core
fiber
Restricted Area
1/2 SM Core + 1/2 Fiber
Diameters - 66 µm dia.
No Loose or No Fixed
Contamination
Monitor
Viewing
Area
No LOOSE
contamination or
particulate fibers
in viewing area. If
not removable in 3
cleaning attempts,
it is defined as
fixed particulate.
Fixed
particles
(<8.0µm in size)
allowed in this area.
CAUTION
Do not attempt to clean ports equipped with yellow Light guide BuildOut (LBO)
attenuators. Attenuators contain a thin glass lens that is extremely fragile. The
LBO will be damaged if cleaned using this method.
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...