Final operations
Ring setup and testing: integration procedures
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
6 - 1 7
............................................................................................................................................................................................................................................................
Final operations
Description
The following procedure ensures that all test signals and cross-connects have been
removed and the 1665 DMX shelf is alarm free and ready for network connection
procedures.
Procedure
........................................................................................................................................................................................................................
1
Select Configuration -> Cross-Connections...
........................................................................................................................................................................................................................
2
Use the Cross-Connection Wizard to Delete leg(s) of an existing cross-connection
associated with CP main-1, Port 1.
........................................................................................................................................................................................................................
3
Select Configuration -> Update System... -> Update All.
........................................................................................................................................................................................................................
4
Verify that no alarm LEDs are lit and no FAULT LED is lit on any circuit pack.
If any alarm is present, refer to 365-373-302,
1665 Data Multiplexer (1665 DMX), Alarm
Messages and Trouble Clearing Guide
.
........................................................................................................................................................................................................................
5
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Clear PM registers
The following steps will clear all the performance monitoring registers:
........................................................................................................................................................................................................................
1
Select Performance -> Initiate PM Registers -> Both.
........................................................................................................................................................................................................................
2
If desired, reconnect the office alarm cable at this time.
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...