
............................................................................................................................................................................................................................................................
Automatic protection switching test
Ring setup and testing: integration procedures
6 - 1 2
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
Automatic protection switching test
Description
This section provides the procedures for verifying the 1665 DMX shelf automatic and
manual protection switching.
Note the following:
•
These tests do NOT simulate circuit pack failures.
•
A properly grounded wrist strap must always be worn while handling circuit packs.
•
Prior to performing each test, the shelf under test must be clear of all alarms (that is,
only green LEDs are lighted).
Main OLIU switch test
........................................................................................................................................................................................................................
1
In order to perform path switching, an add/drop cross-connection must be entered. Select
Configuration -> Cross-Connections... and use the Cross-Connection Wizard to enter an
add/drop cross-connection.
........................................................................................................................................................................................................................
2
Select View -> Protection...
........................................................................................................................................................................................................................
3
Under Path Protection choose Path m-1-1 and click Select.
........................................................................................................................................................................................................................
4
Note the Active Path (m1 or m2).
........................................................................................................................................................................................................................
5
Disconnect the optical fiber connected to the
IN
port on the active path OLIU.
Result:
The MN and then MJ alarm LED should light on the SYSCTL and the
FAULT
LED should flash on the OLIU.
........................................................................................................................................................................................................................
6
Click refresh in the View Protection window.
........................................................................................................................................................................................................................
7
Verify the Active Path has changed (from m1 to m2 or m2 to m1).
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...