Manual switching tests
Operational tests
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
5 - 1 1
............................................................................................................................................................................................................................................................
Manual switching tests
Description
This test will initiate switching commands from the CIT and verify proper switching and
LED indications.
Main OLIU switch test
Important!
An STS-1 cross-connect should still exist from the previous tests.
........................................................................................................................................................................................................................
1
Select Fault -> Protection Switch.
........................................................................................................................................................................................................................
2
Under Path Protection choose Path m-1-1.
........................................................................................................................................................................................................................
3
Click Select.
........................................................................................................................................................................................................................
4
Note the Active Path:.
........................................................................................................................................................................................................................
5
In the Switch Type: pull-down, choose Manual.
........................................................................................................................................................................................................................
6
Click Apply.
Requirement:
The ring that was active in
is no longer active and the other ring
is now active.
........................................................................................................................................................................................................................
7
In the Switch Type pull-down, choose Clear.
........................................................................................................................................................................................................................
8
Click Apply.
........................................................................................................................................................................................................................
9
to verify a switch back to the original ring.