Automatic protection switching and alarm test
Operational tests
5 - 8
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
Automatic protection switching and alarm test
Description
This section provides the procedures for verifying the 1665 DMX shelf automatic
protection switching.
Note the following:
•
These tests do NOT simulate circuit pack failures.
•
The tests will verify proper alarm reporting and LED indications when circuit
packs are removed.
•
All protected circuit packs will be tested.
•
A properly grounded wrist strap must always be worn while handling circuit
packs.
•
This test is performed with the 1665 DMX shelf optically looped back on itself
(that is, with the IN of the OLIU M1 looped to the OUT of the OLIU M1, and the
IN of the OLIU M2 looped to the OUT of the OLIU M2).
•
Prior to performing each test, the shelf under test must be clear of all alarms (that
is, only green LEDs are lit).
A properly grounded ESD wrist strap MUST be worn when handling circuit packs.
Unterminated optical connectors may emit laser radiation. Do not view beam with
optical instruments.
Main OLIU switching test
Use this procedure to test the following Main OLIU circuit packs in a UPSR (default)
configuration:
CAUTION
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
CAUTION
ESD hazard
WARNING
Laser hazard
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...