Overview
The following table lists the power requirements for the 1665 DMX High-Capacity shelf.
Table 2-1
1665 DMX High-Capacity shelf power supply requirements
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
Verify that the frame or structure into which the 1665 DMX High-Capacity shelf is
installed is properly grounded.
........................................................................................................................................................................................................................
2
Verify that both circuit breakers on the 1665 DMX High-Capacity shelf are in the ON
position. These breakers are located on the front of the 1665 DMX High-Capacity shelf.
........................................................................................................................................................................................................................
3
Disconnect the power cables from the backplane connectors (P15 from J15 and P14 from
J14).
Item
Description
Voltage range, all components
-40.0V to -60.0V DC
Power feeders
two -48V power feeders
[BREAKER (A) and
BREAKER)B)]
Circuit breakers (two per
shelf)
20.0A or 30.0 A