
Configuration Commands
Page 276
7750 SR OS Interface Configuration Guide
e3
Syntax
e3
sonet-sdh-index
Context
config>port>tdm
Description
This command enables the context to configure E-3 parameters. E-3 lines provide a speed of 44.736
Mbps and is also frequently used by service providers. E-3 lines carry 16 E-1 signals with a data rate
of 34.368 Mbps.
A E-3 connection typically supports data rates of about 43 Mbps. A E-3 line actually consists of 672
individual channels, each supporting 64 Kbps. E-3 lines are used mainly by Service Providers to
connect to the Internet backbone and for the backbone itself.
Depending on the MDA type, the E-3 parameters must be disabled if clear channel is enabled by
default (for example, on the m12-ds3e3 MDA). Clear channel is a channel that uses out-of-band
signaling, not in-band signaling, so the channel's entire bit rate is available. Channelization must be
explicitly specified. Note that if E-3 nodes are provisioned on the channelized SONET/SDH MDA
you must provision the parent STS-1 SONET/STM0 SDH path first.
North America uses the T-Carrier system while Europe uses the E-Carrier system of transmission,
using multiples of the DS system. Digital signals are carried inside the carrier systems.
The
no
form of this command disables E-3 capabilities.
bert
Syntax
bert
{
2e3
|
2e9
|
2e11
|
2e15
|
2e20
|
2e20q
|
2e23
|
ones
|
zeros
|
alternating
}
duration
duration
no bert
Context
config>port>tdm>ds1
config>port>tdm>ds3
config>port>tdm>e1
config>port>tdm>e3
Description
This command initiates or restarts a Bit Error Rate Test (BERT) on the associated DS-1/E-1 or DS-3/
E-3 circuit.
The associated DS-1, E-1, DS-3, or E-3 must be in a shutdown (admin down) state to initiate this test.
The
no
form of the command terminates the BERT test if it has not yet completed.
Notes:
• This command is not saved in the router configuration between boots.
• The 4-port OC-3/STM-1 and the 1-port OC-12/STM-4 ASAP MDA supports up to 28 concur-
rent BERT tests per MDA. The 4-port and 12-port DS-3/E-3 ASAP MDAs support a single
BERT test per MDA. An attempt to configure more BERT tests can result in an error indicating
an operation failure due to resource exhaustion.
• If the ASAP MDA BERT error insertion
rate
command is executed when tests are running, it
will not take effect until test is restarted.
Default
2e3
Summary of Contents for 7750 SR OS
Page 6: ...Page 6 7750 SR OS Interface Configuration Guide Table of Contents ...
Page 8: ...Page 8 7750 SR OS Interface Configuration Guide List of Tables ...
Page 10: ...Page 10 7750 SR OS Interface Configuration Guide List of Figures ...
Page 14: ...Preface Page 14 7750 SR OS Interface Configuration Guide ...
Page 16: ...Getting Started Page 16 7750 SR OS Interface Configuration Guide ...
Page 184: ...Card MDA and Port Command Reference Page 184 7750 SR OS Interface Configuration Guide ...
Page 438: ...Debug Commands Page 438 7750 SR OS Interface Configuration Guide ...
Page 444: ...Index Page 444 7750 SR OS Interface Configuration ...