SNMP
7705 SAR OS System Management Guide
167
Configuration Notes
This section describes SNMP configuration caveats.
•
To avoid management systems attempting to manage a partially booted system,
SNMP will remain in a shutdown state if the configuration file fails to complete
during system startup. While shut down, SNMP gets and sets are not processed.
However, notifications are issued if an SNMP trap group has been configured.
In order to enable SNMP, the portions of the configuration that failed to load must be
initialized properly. Start SNMP with the
config>system>snmp>no
shutdown
command.
•
Use caution when changing the SNMP engine ID. If the SNMP engine ID is changed
in the
config>system>snmp>engineID
engine-id
context, the current
configuration must be saved and a reboot must be executed. If the configuration is
not saved and the system is not rebooted, the previously configured SNMP
communities and logger trap-target notify communities will not be valid for the new
engine ID.
Reference Sources
For information on supported IETF drafts and standards as well as standard and proprietary
MIBS, refer to
Standards and Protocol Support
.
Summary of Contents for 7705 SAR
Page 10: ...List of Figures 10 7705 SAR OS System Management Guide...
Page 14: ...About This Guide 14 7705 SAR OS System Management Guide...
Page 64: ...Security Configuration Procedures 64 7705 SAR OS System Management Guide...
Page 168: ...Configuration Notes 168 7705 SAR OS System Management Guide...
Page 354: ...Standards and Protocol Support 354 7705 SAR OS System Management Guide...
Page 356: ...2015 Alcatel Lucent All rights reserved 3HE 09688 AAAA TQZZA Edition 01...