Wrong SDSL unit present
...................................................................................................................................................................................................................................
Alarm identifier
SDSLcWUP
Information
An SHDSL extension board (X12SHDSL) is provisioned, but an extension
board of a different type is present, or the present extension board cannot be
identified.
A proper downloading of the software will not be possible.
Alarm category
Equipment
ASAP
sdsl
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
The red “Fault” LED is lit.
Cause
Wrong extension board inserted, or the inserted extension board is defective.
Actions
Insert an SHDSL extension board, or change the provisioning.