GENERAL DESCRIPTION
The AL-PCI2 is an interface cable that allows high speed
communication between a PC running DL-Windows software
and a compatible Trilogy Digital Lock, Data Transfer Module,
or an AL-PRE proximity card reader. Using the AL-PCI2, the
PC can upload or download programming to/from the lock,
and upload event history.
Compatible Trilogy Digital Locks:
SPECIFICATIONS
Input Power: Supplied by the PC and lock connections
Dimensions: 2
5
/
8
"L x 1¼"H x ¾"W with 5' cord
SYSTEM REQUIREMENTS
•
IBM PC or compatible desktop or notebook computer with
233 MHz or faster processor.
•
At least 10 Mb available on hard drive
•
At least 64 MB of RAM memory
•
Microsoft Windows 95, 98, NT4.0 or higher
•
DL-Windows
•
One unused RS-232 Serial Communications port (Com 1–
4), or USB Port (see NOTE 1).
OPERATION
For details regarding the use of the AL-PCI2, refer to DL-
Windows User Guide OI237.
NOTE 2:
The AL-PCI2 is designed to be used on a 9 pin serial
Com Port. If your computer has a 25 pin Com Port, a
25 pin to 9 pin adapter must be used.
Warning:
Polarity MUST be observed when connecting to the
lock. The tab (–) must plug into the left hole (black).
Trilogy
®
is a registered trademark of Alarm Lock. Windows is a trademark of Microsoft
NOTE 1:
The AL-PCI2 is fully RS-232 compliant and will function prop-
erly with a computer that has an RS-232 compliant serial Com
Port. However, many new notebook computers do not provide
the proper RS-232 compatible Com Port voltage levels re-
quired by the AL-PCI2. In these cases, the AL-PCI2 may not
function properly.
To test a serial Com Port for AL-PCI2 compatibility, attach the
AL-PCI2 to the Com Port and run the DL-Windows loop-back
test. If the loop-back test fails, the Com Port is most likely not
RS-232 complaint.
For new computers with non-RS232 compliant Com Ports, it is
recommended that the AL-PCI2 be connected to the com-
puter’s USB port. Obtain a USB converter (MX1130) from
Alarm Lock Systems. The MX1130 has been fully tested by
Alarm Lock for use with the AL-PCI2.
For more information, or to order, go to the Alarm Lock website
at:
www.alarmlock.com
or contact your distributor.
Application 1
Program the Lock directly using a PC or
Laptop
AL-PCI2
Application 2
Send Trilogy Lock Programs from PC to
AL-DTM for transfer to multiple Digital Locks OR use
the AL-DTM to retrieve system activity reports from
locks to be transferred to the PC.
AL-PCI2
Application 3
Connect the AL-PRE Prox Card Enroller
to the PC to read Prox Cards directly into DL-
Windows.
AL-PCI2
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2005
CONNECTION
Refer to the following wiring diagrams / applications:
WI896E 11/05
•
DL3000
•
DL2800
•
PDL4100
•
DK3000
•
DL3500
•
DL4100
•
DL4500
•
PDL3000
•
PDL3500
•
PDL4500
•
ETDL
•
ETPDL
•
PDK3000