4.1.2. IR LED
Go to
Intercom - Advanced
to configure.
Photoresistor:
The setting is for night vision, when the surrounding
of R26X is very dark, infrared LED will turn on and R26X will turn to
night mode. Photoresistor value relates to light intensity and larger
value means that light intensity is smaller. Users can configure the
upper and lower bound and when photoresistor value is larger than
upper bound, infrared LED will turn on. As contrast, when
photoresistor value is smaller than lower bound, infrared LED will
turn off and device turns to normal mode.
4.1.3. RF Card Code Display Related
Go to
Intercom - Advanced
to configure.
RFID Display Mode:
To be compatible different card number
formats. The default 8HN means hexadecimal.
Figure 4.1.2 IR LED
Figure 4.1.3 RF card code display related