Akuaplus ELITE RD 812X030 Operator'S Manual Download Page 1

Store/Magasin

1 844 666-0155

1 2
3 4

Store/Magasin

1 844 666-0155

DO NOT RETURN THIS PRODUCT TO STORE, CONTACT US. We’re there if you need help.

NE RETOURNEZ PAS CE PRODUIT AU MAGASIN, CONTACTEZ-NOUS.

Nous sommes là si vous avez besoin d’aide.

1 844 666-0155 • [email protected]

2020-04

RD 812X030BL

RD 812X030

ANTICALCAIRE

NON-CLOGGING

ELITE

Shower post system 3-setting balanced pressure valve 

(hand shower only, shower head only or both simultaneously)

Système de barre murale avec valve à pression équilibrée, 3 réglages 

(douchette seule, pommeau seul ou les 2 simultanément)

Operators’ Manual

Guide de l’utilisateur

Summary of Contents for ELITE RD 812X030

Page 1: ...avez besoin d aide 1 844 666 0155 question dimex360 com 2020 04 RD 812X030BL RD 812X030 ANTICALCAIRE NON CLOGGING ELITE Shower post system 3 setting balanced pressure valve hand shower only shower he...

Page 2: ...th a soft cotton cloth INSTALLATION TIPS Cover your workspace to avoid damaging it or losing parts First tighten the union nuts manually Then use a wrench to hold the fitting and a second wrench to ti...

Page 3: ...wall plate Plaque murale en laiton 13 Divertor knob Bouton de l inverseur 14 Handle Poign e 15 Elbow fitting Raccord coud 16 Flange made in brass Collerette de douche en laiton 17 Brass shower arm Br...

Page 4: ...cm MIN 48 122 cm MAX Suggest position Montage sugg r 20 cm 18 5 cm 40 cm 8 cm 1 3 cm 1 2 1 9 cm 5 5 cm 2 2 cm 1 2 66 cm 60 cm 7 cm 60 mm 82 mm 27 35 mm 11 mm 1 2 po in NPT 1 2 po in 15 cm 59 po in 1 5...

Page 5: ...re the connections are watertight by slowly opening the water supply In case of a leak shut off the water supply and tighten connectors with the appropriate tool V rification des raccordements Assurez...

Page 6: ...iltration dans le mur Before drilling holes in the shower wall place product against the wall to mark holes location Use the appropriate bit for drilling your wall Avant de percer la cloison placez le...

Page 7: ...an remove the flow limiters in the hand shower A and the shower head B Si vous n avez pas assez de pression vous pouvez retirer les limiteurs de d bit dans la douchette A et de la pomme de douche B B...

Page 8: ...will need to clean it in a solution of half vinegar and half hot water ideally overnight brush and then rinse it under clean water Apply plumbing grease to the O rings replace the cartridge Align the...

Page 9: ...ne dans un endroit s r et sec pour consultation ult rieure PROBLEM PROBABLE CAUSE SOLUTION Cold water and hot water are reversed Bad connection of hot and cold water supplies Invert the hot and cold w...