AK3000 DS3 Product Family  

Document 180-0006-001 R08 

 
 
 
 

   Part #                    Description                                    

  CLEI Code   

   Kit Part #                    Description 

  

AK300C 

CO DS3 line card, Full DS3 at CSA, Line powering  VAUIACMJ  

AK3000C 

CO DS3 Kit (AK300C & AK100S) 

AK301C 

CO DS3 line card, Full DS3 at CSA 

VAUIACNJ AK3001C 

CO 

DS3 

Kit (AK301C & AK100S) 

AK300R 

RT DS3 line card, Full DS3 at CSA 

VAUIACPJ 

AK3000R 

RT DS3 Kit (AK300R & AK100S) 

AK100S 

1RU Shelf (w/ AK100F fan module)  

VAMB410F  

 

   

 

The AK3000 DS3 product family enables point to point transport of DS3 and fractional DS3 services over bonded pairs of copper, 
optimized for CSA distances (9kft 26AWG or 12kft 24AWG).  The AK3000 family consists of DS3 Central Office and Remote 
cards that plug into a 1RU high housing for 19” and 23” racks and for wall mounting.  The remote card is either line powered by 
the Central Office card or locally powered.  Aktino products utilize a technology “MIMO on DMT” which uses coordinated signal 
processing over multiple transceivers to achieve significant performance improvements over standard DSL technology.  Refer to 
the AK3000 DS3 Technical Practice (180-0005-001) for more comprehensive information and troubleshooting. 

 

Installation is identical for both the CO and RT ends. 

#1 Mounting 

(see Figure 1) 

 

The AK3000 Family’s shelf (AK100S) can be mounted in 
either 19 inch or 23 inch racks.  The AK100S chassis 
includes flanges for both 19 and 23 inch mounting.  Screws 
for mounting to both the chassis and the rack are included.  
Mounting holes are provided for flush or mid mount.  The 
unit can also be mounted on a wall using either 19 or 23 inch 
flanges.  An optional hinged bracket (AK100B) is available 
for easier wall mounted access. 

 
 
 
 
 
 
 
 
 
 

#2 Connections 

(see Figure 2)

Frame Ground Connection 

The Ground Lug located on the right hand side of the back 
panel can accommodate up to 6 AWG wire.  Use a wire 
gauge for grounding at least as heavy as the power wiring.  
Attach the grounding wire to the AK100S Ground Lug to a 
nearby grounding screw on the equipment rack or facility 
ground.  

Note that the ground connection is required for 

proper system operation.

 

Power Connection 

A 7.5A to 10A UL listed fuse/circuit breaker must be 
installed ahead of this unit. 

 

To access the power block, the Protective Cap located on the 
left hand side of the back panel must be removed.  Unscrew 
the captive screw on the right side of the Protective Cap, 
slide the cap to the left and lift off.  Labels of the power 
block and wirewrap connections are silk screened on the 
Protective Cap as well as the back panel. 

 

Two redundant power buses are provided (A and B).  The 
two power inputs are identical and can be used for redundant 
power configurations. 

 

 

Insert the ends of the -48 Vdc and Return power wires (16 
AWG wire is recommended) into the A and B holes on the 
left side of the power block.  Route the power wires towards 

the left of the back panel so that the Protective Cap can be 
reinstalled. 

Alarm Connections 

The alarm wirewrap connections are located under the 
Protective Cap.  Unscrew the captive screw on the right side 
of the Protective Cap, slide the cap to the left and lift off.  
Labels of the wirewrap connections are silk screened on the 
Protective Cap as well as the back panel.  Each alarm 
consists of a three pin wire wrap header.  These are generally 
only used on the CO end. 

DS3 Connection 

Attach the transmit and receive DS3 coax cables to the In 
and Out BNC connectors on the back panel.  The IN 
connector’s shield can be grounded or opened by the slide 
switch below the IN connector.  Generally, only one end of 
the DS3 coax cable shield should be grounded. 

AK3000 DS3 System Quick Installation 

 

                 1-888-AKTINO9

Figure 1 Mounting 