background image

Valve Actuator moves at the end 
of the open or closed function.

Loose screws

While some motion is normal from torque, excessive movement 
may be caused by loosened screws.
Before tightening the screws, remove them and apply Permabond 
LM 113 or Loctite 222 and retighten.

No Power to the 
Controller

Bad wiring
Open breaker or blown fuse
Power not connected.

Check all power connections, wires, fuses or breakers.
Be sure a separate power wire is connected to any Controller used 
as an Auxiliary.

Valve Actuator does not work. 
Motor does not drive.

1. No signal from the Controller 
    to the Actuator Motor.
2. Defective Actuator Motor
3. Worm Gear system jammed.
4. Planet Gear system jammed.

1. Check all connectors are fully engaged.
    Check the voltage through the Wiring Harness   
    should be at least 11.5 volts for 12 volt systems and 
    22 volts for 24 volt systems. Check the signal from 
    the Controller.
2. Remove the Motor from the Actuator and operate 
    the Motor to be sure the Motor Shaft turns freely.
3. Check the Worm Gear. Operate the Valve using the 
    Manual Override.
4. Remove the Motor and check the Planet Gears.

Motor Runs but Valve does not 
operate

1. Grove Pin is missing from the 
    Shaft.
2. Gear Sector is not engaging 
    the Worm Gear.
3. Motor Shaft is disengaged 
    from the Planet gears.

1. Check the Groove Pin is fully engaging the Worm 
    Gear and Shaft.
2. Check if the Worm Gear and Sector Gear are 
     engaged.
3. Remove the Motor and check for engagement of the 
    Motor Shaft and Planet Gears.

Valve closes when the OPEN 
Button is pressed and vice versa.

1. Sector Gear is in the wrong 
    position.
2. Cable wiring is reversed.

1. Reposition the Sector Gear.
2. Replace the Cable.

Valve OPEN/CLOSE LED’s switch 
immediately from Red to Green 
and vice versa.

1. Wiring
2. Mechanical Binding

1. Check wiring as explained in Problem #1.
2. Remove the Motor and check the Shaft turns freely. Also, oper-
ate the Valve manually via the Override to check for binding.

APPENDIX

Mating Weather-Pack Connectors for Power Cable

A Mating Weather-Pack connector must be used to connect to the power source. 
DO NOT CUT THE CONNECTOR on the power wire of the controller.
Doing so will void the warranty.
Part number 9300-0058 is a packet of (5) mating Weather-Pack connections. 

Wiring Harnesses

Part Number 

 

Description

7-21-290  

 

10’ long (standard length)

7-21-381   

 

15’ long

9303-0016 

 

20’ long

9303-0012 

 

30’ long (utilizes Potting Shells and 10 gauge wire)

9303-0013 

 

38’ long (utilizes Potting Shells and 10 gauge wire)

9303-0014 

 

50’ long (utilizes Potting Shells and 8 gauge wire)

Auxiliary Cables

Part Number 

 

Description

9300-0052 

 

10’ long (standard length)

9300-0055 

 

25’ long

9300-0056 

 

50’ long

ISO 9001 REGISTERED COMPANY

PHONE: 330.264.5678 or 800.228.1161  I  FAX: 330.264.2944 or 800.531.7335  I  www.akronbrass.com

WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace 
product which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. 

We will not be responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; damage; failure to 
follow our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY 
STATEMENT, AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, 
incidental or indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty.

© Premier Farnell Corporation. 2012 All rights reserved. No portion of this can be 

reproduced without the express written consent of Premier Farnell Corporation.

 

REVISED:  4/12

Style 9313 Controller Ordering Information

Part Number

Description

9313-0001

Controller Only

9313-0002

Controller w/ 10’ Wiring Harness

9313-0003

Controller w/ 10’ Auxiliary Cable

STYLE 9313 CONTROLLER 

    INSTALLATION & OPERATING INSTRUCTIONS

The Style 9313 Controller from Akron is designed to provide reliable and accurate valve control with valve position 
indication through 10 LED (Light Emitting Diodes) indicators identifying the degree of Open/Close.

Features of the Akron Style 9313 Controller include:
 

Protected against EMI (Electro Magnetic Interference), both incoming and outgoing

 

Programmable Auto Open (not preset)

 

Works with both 12 and 24 Volt systems

 

Retrofits to existing apparatus

 

4 ¼” square face

 

Meets all aspects of NFPA 1901

 

Carries Akron’s 5 year warranty against manufacturing defects

Standard Components
 

Controller

 

Wiring Harness for connection to the valve-10’ length standard

Note: the Controller is designed for use only with Akron Brass Electric Valves. Do not use with any other manufacture of valve. Doing 
so will void any warranty.

INSTALLATION INSTRUCTIONS

Select the mounting location for the Controller. The Controller can be mounted from the outside with (4) Screws and 
Delrin Nuts (included). Torque requirement is 6-8 lb-in for the nuts. The unit requires 2 ½” clearance behind the panel. Dimensions 
for a panel cutout are shown in figure #1.

Warning:

 The Controller is a sealed unit. Disassembly of the unit will void any warranty. There are no user serviceable parts in the 

Controller. If service is required the unit should be returned to the factory. Also, do not cut any connections. Doing so will void any 
warranty and prevent product returns.

Note: The Valve and Auxiliary wires are plugged prior to shipment. These plugs must be removed before connections can be made. If 
a lead is not being utilized, the plug should be left in place to prevent moisture damage.

CONTROLLER LEADS

Each Controller has three (3) Connectors extending from the back of the unit.

Power Connection lead

The Controller Power connection utilizes a 2 prong Weather-Pack connector. A mating Weather-Pack connector is required (cus-
tomer supplied-see appendix for purchasing information). Proper wire gauge is required to assure a quality connection. 12 gauge wire 
is recommended. Heavier gauge wire is required for runs over 10’.

Note: when using larger than 12 gauge wire, be sure to use a 12 gauge connector and splice after the connector so as to not void any 
warranty. The splice should be made close to the Controller.

121568