AKO-14721
Thermostat
Panel-mounted
1: 7A cos
ϕ
=1 (SPDT)
12V
ⵑ
, ±15%, 173 mA
ⵑ
2: 7A cos
ϕ
=1 (SPDT)
INSTALLATION:
Thermostat:
The thermostat must be installed in a place away from vibrations, water and corrosive gas and where the ambient
temperature is within the range in the technical specifications.
For protection level IP65, the joint between the device and the surrounding of the panel space where it is installed
must be properly made.
Probe:
For correct readings, the probe must be installed in a place free of thermal effects other than the temperature to be
measured or controlled.
This diagram shows how the probe must be connected:
Functions:
UP key
During programming, increases the figure being displayed.
DOWN key
During programming, lowers the figure being displayed.
Conexionado:
Conectar las regletas enchufables según esquema en etiqueta de características de los
aparatos.
Los cables para el conexionado de los contactos de los relés, deberán tener una sección
de entre 1mm
2
y 2,5 mm
2
.
La sonda y su cable correspondiente
NUNCA
deben instalarse en una conducción junto
con cables de potencia, control o alimentación, pudiéndose prolongar sin que produzca
desviación.
Connections:
Connect plugging terminals according to the rating plate diagram..
Section of connecting wires for relays contacts must be between 1mm
2
and 2,5 mm
2
.
The probe and its corresponding cable should
NEVER
be installed in ducting along with
mains, control or power supply wiring, probe cables can be extended and no deviation
will appear.
www.ako.com
HOJA TÉCNICA
1472H100
Edición 06
(01 de 02)
E
Termostato digital hasta 600ºC, 12 V, 2 relés
para sondas Pt 100 y montaje en panel
AKO-14721
GB
Digital, 12 V, two-relay, panel mounted thermostat
for Pt 100 probes, up to 600 °C
AKO-14721
DESCRIPCIÓN GENERAL:
Termostato electrónico panelable adecuado para visualizar, controlar y regular generadores de frío o de calor.
DATOS TÉCNICOS:
Rango de temperatura:
..........................................................................................................................................
-50ºC a 600ºC
Entrada sonda Pt 100: ....................................................................Ref.
AKO-15184, AKO-15185A, AKO-15595, AKO-15596
Precisión del controlador: ................................................................................................................................................
⫾
0,5ºC
Temp. ambiente de trabajo: ........................................................................................................................................5ºC a 40ºC
Temp. ambiente de almacenaje:..............................................................................................................................-30ºC a 70ºC
VERSIÓN:
MODELO
FUNCIÓN ANCLAJE
RELÉS
ALIMENTACIÓN
AKO-14721
Termostato
Panelable
1: 7A cos
ϕ
=1 (SPDT)
12V
ⵑ
,
⫾
15%,173 mA
ⵑ
2: 7A cos
ϕ
=1 (SPDT)
- de montaje independiente
- de característica de funcionamiento automático acción Tipo 1.B
- para utilización en situación limpia
-soporte lógico (software) clase A
Clasificación dispositivo de control:
INSTALACIÓN:
Termostato
:
El termostato debe ser instalado en un sitio protegido de las vibraciones, del agua y de los gases corrosivos,
y donde la temperatura ambiente no supere los valores reflejados en los datos técnicos.
Para que el equipo tenga un grado de protección IP65 deberá instalarse correctamente la junta entre el
aparato y el perímetro del hueco del panel donde deba montarse.
Pt100
Blanco /
White
Rojo /
Red
Rojo /
Red
Sonda:
Para que la lectura sea correcta, la sonda se ha de instalar en un sitio sin influencias térmicas ajenas a la
temperatura que se desea medir o controlar.
La conexión de la sonda se realiza de acuerdo con el siguiente esquema:
Anclaje:
Para la fijación del aparato situar los anclajes
1
sobre las guías
2
en la posición de la
figura.
Desplazar el anclaje en el sentido de la flecha.
Presionando la pestaña
3
puede desplazarse el anclaje en sentido contrario a la flecha.
máx.
18 mm
3
2
1
61,5
70,5
28,5
HUECO PANEL
PANEL CUT-OUT
44
Fonctions:
Tecla SUBIR
En programación, sube el valor que se está visualizando.
Tecla BAJAR
En programación, baja el valor que se está visualizando.
Pulsando simultáneamente durante 10 segundos se entra en el menú de programación.
Pulsando simultáneamentese fija el nuevo valor.
LEDS indicadores:
LED 1
permanente:
Indica que está activado el relé 1.
intermitente:
Indica que por temperatura detectada por la sonda el relé 1 tendría que estar activado, pero no lo
está por alguna condición de programación.
LED 2
permanente:
Indica que está activado el relé 2.
intermitente:
Indica que por temperatura detectada por la sonda el relé 2 tendría que estar activado, pero no lo
está por alguna condición de programación.
LED PR intermitente:
Fase programación punto de ajuste o parámetros.
FUNCIONES DEL FRONTAL
PRG
PR
ºC
SET
1
2
LED 2
LED 1
TECLA SUBIR
UP KEY
LED PR
TECLA BAJAR
DOWN KEY
Pulsando durante 5 segundos se entra en el menú de ajuste de las temperaturas.
Los valores de fábrica, de AJUSTE DE TEMPERATURA (Set Point) 1 y 2 por defecto son de 0°C.
AJUSTES DE LA TEMPERATURA (SET POINT):
SP1 = Punto de ajuste R1
SP2 = Punto de ajuste R2
+ Held down simultaneously for 10 seconds brings up the programming menu.
+ Held down simultaneously enters the new value.
Indicator LEDs:
LED 1 constant:
Shows relay 1 is on.
flashing:
Means relay 1 should be on according to the temperature detected by the probe, but is not, owing to a
programming condition.
LED 2 constant:
Shows relay 2 is on.
flashing:
Means relay 2 should be on according to the temperature detected by the probe, but is not, owing to a
programming condition.
LED PR flashing:
Programming set point or parameters.
The default (factory) setting for SET POINTS 1 and 2 are 0ºC.
GENERAL DESCRIPTION:
Panel-mounted electronic thermostat, suitable for display, control and regulation of heat or cold generators.
TECHNICAL SPECIFICATIONS:
Temperature range: ..............................................................................................................................................-50ºC to 600ºC
Pt 100 probe entry: ........................................................................Ref.
AKO-15184, AKO-15185A, AKO-15595, AKO-15596
Controller accuracy: ..........................................................................................................................................................±0,5ºC
Ambient working temperature: ..................................................................................................................................5ºC to 40ºC
Ambient storage temperature:................................................................................................................................-30ºC to 70ºC
FRONT PANELS FUNCTIONS:
VERSION:
Fastening:
To fix the unit, place the fasteners
1
over the sliders
2
as shown in the figure.
Move the fasteners in the direction of the arrow.
By pressing tab
3
, the fasteners may be moved in the opposite direction to the arrow.
TEMPERATURE SET POINT:
MODEL
FUNCTION MOUNTING
RELAYS
POWER
SUPPLY
5 Seg.
5 Sec
.
AJUSTE ACTUAL
PRESENT
SETTING
INDICACIÓN
TEMPERATURA
TEMPERATURA
DISPLAY
NUEVO AJUSTE
NEW SETTING
AJUSTE ACTUAL
PRESENT
SETTING
SP1= Set Point for R1
SP2= Set Point for R2
SELECCIÓN
SELECTION
NUEVO AJUSTE
NEW SETTING
ACEPTAR EL NUEVO
ENTER NEW VALUE
VARIAR VALOR
CHANGE VALUE
VISUALIZAR
DISPLAY
MENU DE AJUSTE
SETTINGS MENU
Holding it down for 5 seconds brings up the temperature
adjustment menu.
- with independent mounting
- with characteristic of automatic operation action, Type 1.B
- to be used in clean situation
-logical medium (software) class A
Control device classification:
- Hold the key down for 5 seconds. This opens the SP1 or SP2 setting menu
(the PR led will flash).
- Press the or key to select SET POINT 1 or SET POINT 2.
- Press the + keys simultaneously to show the setting you want to change.
- Press the or keys to change the SET POINT to the figure you want.
- Press the + keys simultaneously to enter the new figure. When you do this,
the display shows the temperature again and the PR led stops flashing.
NOTE: If no key is pressed for 30 seconds during any of these steps, the controller
automatically returns to temperature display, neither of the SET POINTS being
changed.
- Pulse la tecla durante 5 segundos. Permite entrar en el menú de ajuste SP1
o SP2 y se iluminará el led PR de forma intermitente.
- Pulse las teclas ó para seleccionar el AJUSTE 1 o AJUSTE 2.
- Pulse las teclas
+ simultáneamente para visualizar el ajuste que desea mo-
dificar.
- Pulse las teclas ó para modificar el AJUSTE (Set Point) al valor deseado.
- Pulse las teclas + simultáneamente para fijar el nuevo valor. Al realizar esta
operación, el display volverá a la situación de indicación de temperatura y el led
PR dejará de iluminarse de forma intermitente.
NOTA: Si no se pulsa tecla alguna durante 30 segundos en cualquiera de los
pasos anteriores, el controlador volverá automáticamente a la situación de
indicación de temperatura, sin modificar los valores de los AJUSTES deseados
(Set Point).
MODOS DE FUNCIONAMIENTO Y CONTROL DE LOS RELÉS
P00=0 Actuación ON-OFF
Funcionamiento CALOR P02=1
ON
OFF
SP2
Temp.
arranque
Temp.
paro
Temp.
arranque
Temp.
paro
SP2 + C12
C12>0
SP2
SP2 - C12
C12<0
ON
OFF
SP2
Temp.
arranque
Temp.
paro
Temp.
arranque
Temp.
paro
SP2 + C12
C12>0
SP2
SP2 - C12
C12<0
ON
Funcionamiento FRÍO P01=0
Funcionamiento FRÍO P02=0
Funcionamiento CALOR P01=1
OFF
SP1
Temp.
arranque
Temp.
paro
Temp.
arranque
Temp.
paro
SP1 + C11
C11>0
SP1
SP1 - C11
C11<0
ON
OFF
SP1
Temp.
arranque
Temp.
paro
Temp.
arranque
Temp.
paro
SP1 + C11
C11>0
SP1
SP1 - C11
C11<0
ON
OFF
ON
OFF
SP1 - C15
SP1 + C15
SP1
RELÉ 2
RELÉ 1
RELÉ 2
P00=1 Zona Neutra
RELÉ 1
RELAY CONTROL AND OPERATING MODES
P00=0 ON-OFF Switching
HEAT operation P02= 1
ON
OFF
SP2
SP2 + C12
C12>0
SP2
SP2 - C12
C12<0
ON
OFF
SP2
SP2 + C12
C12>0
SP2
SP2 - C12
C12<0
ON
COLD operation P01=0
COLD operation P02=0
HEAT operation P01= 1
OFF
SP1
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
SP1 + C11
a C11>0
SP1
SP1 - C11
C11<0
ON
OFF
SP1
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
Temp.
ON
Temp.
OFF
SP1 + C11
C11>0
SP1
SP1 - C11
C11<0
ON
OFF
ON
OFF
SP1 - C15
SP1 + C15
SP1
RELAY 2
RELAY 1
RELAY 2
P00=1 Neutral Zone
RELAY 1
+
+