D12 VR MANUAL
D12 VR MANUAL
16
17
TEcHNIcAL dATA
TEcHNIcAL dATA
5
Technical data
Type:
dynamic pressure gradient transducer
Polar pattern:
cardioid
Frequency range:
17 - 17,000 Hz (±2 dB)
Sensitivity at 1,000 Hz passive:
1,2 mV/Pa ± -58 dBV
Impedance at 1000 Hz:
< 200 ohms
Recommended load impedance:
> 1000 ohms
Max. SPL for 0.5 % THD:
164 dB SPL
Environment:
temperature range: -10 °C to +70 °C
Relative humidity at +20° C: 90%
Connector Type:
3-pin male standard XLR
Connector Wiring:
Pin 1: ground pin
Pin 2: AF (in phase)
Pin 3: AF (out phase)
Housing Material:
metal
Finish:
front grille: glossy galvanized nickel matte
rear grille: matte black paint
Dimensions (H x W x D):
125 mm x 101 mm x 66 mm
Weight:
500 g
This product conforms to the standards listed in the Declaration of Conformity. You can request the Declaration of Conformity
by e-mail from
.
Frequency response D12 VR
Green - switch position left
Red -
position middle
switch
Blue -
position
switch
right
D12 VR 0°
D12 VR 180°
Polar Pattern D12 VR
Green - switch position left
Red -
position middle
switch
Blue -
position
switch
right
D12 VR 0°
D12 VR 180°