Reverse Cycle Inverter Air Conditioner

INSTALLATION MANUAL

Model Number

 

TAK-9000-25 

TAK-12000-32 
TAK-18000-50 
TAK-24000-70

Summary of Contents for TAK-12000-32

Page 1: ...mpo org PROTECT YOUR WARRANTY This unit must be installed by a registered licensed installer as required by Government regulations N13275 Reverse Cycle Inverter Air Conditioner INSTALLATION MANUAL Mod...

Page 2: ...rt 1300 886 649 AUS 0800 836 761 NZ info tempo org 2 Contents 03 General Safety Instructions 04 Product Overview 07 Selecting the Installation Place 09 Installation 17 Wiring Diagrams 18 Information f...

Page 3: ...nt system Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner Voltage Ensure that the mains voltage corresponds to that stamped on the ra...

Page 4: ...door unit is installed outdoors on the ground or on a wall on suitable brackets Technical data of the air conditioner are printed on the labels placed on the indoor and outdoor units 1 2 3 6 4 5 9 11...

Page 5: ...17 15 16 14 12 13 14 15 11 Fig 2 B Outdoor Unit Parts No Part 11 Air outlet grille 12 Outdoor unit rating label 13 Cover 14 Gas valve 15 Liquid valve NOTE The diagrams throughout this manual are for i...

Page 6: ...ipe 19 Wall bushing 20 Pipe insulation open tube 21 Binding tape 22 Rubber mat for outdoor unit 23 Screws plugs x6 24 Drainage mouth D Other inclusions not pictured Remote control holder for wall moun...

Page 7: ...Reverse Cycle Inverter Air Conditioner are for use by an appropriately qualified installer Do not try to install the air conditioner on your own doing so will expose you to danger and void the warrant...

Page 8: ...lation diagram Fig 6 Only persons and or companies qualified and experienced in the installation service and repair of refrigerant products should be permitted to do so The purchaser must ensure that...

Page 9: ...rfectly level position vertically and horizontally Drill 32mm deep holes in the wall to fix the plate Use a drill bit to fit the 6mm plugs supplied Insert the plastic anchors into the hole Fix the mou...

Page 10: ...nt earth connection must be ensured The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overv...

Page 11: ...ing two wrenches working in opposite directions Fig 12 Water drainage from the indoor unit The condensed water drainage from the indoor unit is fundamental for the success of the installation Place th...

Page 12: ...onnection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the...

Page 13: ...ng The unit must be installed following all relevant local regulations Water drainage from the outdoor unit Condensed water and ice formed in the outdoor unit while in heating mode Fig 15 can be drain...

Page 14: ...humidity from the refrigerant circuit by using a vacuum pump Fig 18 Detailed instructions follow on the next page Tighten the flare nuts using two wrenches taking care not to damage the pipes Fig 17 I...

Page 15: ...mm Hg has been reached With the vacuum pump still in operation close the low pressure knob on the vacuum pump coupling Stop the vacuum pump Open the 2 way valve by turn and then close it after 10 seco...

Page 16: ...water can enter Indoor unit test Does the ON OFF switch work properly Do the HEATING COOLING and FAN modes operate normally Do the TIMER ON and TIMER OFF functions operate properly Does each indicato...

Page 17: ...After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org 17 Wiring Diagram...

Page 18: ...refrigerant R410A R410A R410A R410A Max distance between indoor and outdoor unit 15m 15m 15m 15m Additional gas charge 20g m 20g m 30g m 30g m Max difference between level 5m 5m 5m 5m Tightening torqu...

Page 19: ...L min 1 0mm2 AWG18 1 0mm2 AWG18 1 5mm2 AWG16 2 5mm2 AWG14 E min 1 0mm2 AWG18 1 0mm2 AWG18 1 5mm2 AWG16 2 5mm2 AWG14 Connection Supply Cable N min 1 0mm2 1 0mm2 1 5mm2 0 75mm2 L min 1 0mm2 1 0mm2 1 5mm...

Page 20: ...A Max Power Input Cooling 1300W Heating 1500W Room size suitability 9 16m2 Rated Voltage 220 240V AC Rated Frequency 50Hz Ingress Protection Outdoor Unit IPX4 Electric Shock Protection Outdoor Unit Cl...

Page 21: ...A Max Power Input Cooling 1150W Heating 1400W Room size suitability 15 23m2 Rated Voltage 220 240V AC Rated Frequency 50Hz Ingress Protection Outdoor Unit IPX4 Electric Shock Protection Outdoor Unit C...

Page 22: ...A Max Power Input Cooling 2300W Heating 2450W Room size suitability 25 40m2 Rated Voltage 220 240V AC Rated Frequency 50Hz Ingress Protection Outdoor Unit IPX4 Electric Shock Protection Outdoor Unit C...

Page 23: ...A Max Power Input Cooling 2800W Heating 2900W Room size suitability 30 50m2 Rated Voltage 220 240V AC Rated Frequency 50Hz Ingress Protection Outdoor Unit IPX4 Electric Shock Protection Outdoor Unit C...

Page 24: ...After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org Instruction Manual Revision Index Version No Issue Date Description V1 0 01 March 2016 Original release...

Reviews: