PROTECT YOUR WARRANTY
This unit must be installed by a registered,
licensed installer as required by
Government regulations.
INSTALLATION MANUAL
Model Number AK-T51R32
5.1kW Reverse Cycle Inverter
Split System Air Conditioner
Page 1: ...WARRANTY This unit must be installed by a registered licensed installer as required by Government regulations INSTALLATION MANUAL Model Number AK T51R32 5 1kW Reverse Cycle Inverter Split System Air...
Page 2: ...00 886 649 AUS 0800 836 761 NZ info tempo org Contents 03 Installation Safety Instructions 08 Product Overview 11 Selecting the Installation Place 13 Installation 21 Information for the Installer 26 O...
Page 3: ...s to that stamped on the rating plate Keep the switch or power plug clean Check and ensure that the socket is suitable for the plug The appliance must be fitted with means for disconnection from the s...
Page 4: ...y operating sources such as open flames an operating ignition gas appliance or an operating electric heater This air conditioner has been fully charged with refrigerant at the factory Should a recharg...
Page 5: ...he allowable maximum charge in a room in kg M is the refrigerant charge amount in the appliance in kg Amin is the required minimum room area in m2 A is the room area in m2 LFL is the lower flammable l...
Page 6: ...The air inlets and outlets of both indoor and outdoor units should not be surrounded by obstacles or close to any hear source or combustible and or explosive environment The indoor unit inlet and outl...
Page 7: ...refrigerant concentration detector which can realise two level audible and visual alarm its error must be not more than 10 C The concentration detectors should be calibrated regularly D It is necessa...
Page 8: ...and an electrical connecting cable The indoor unit is installed on a wall of the room to be air conditioned it must not be installed in a laundry or similar room with high humidity levels The outdoor...
Page 9: ...tions in this manual may vary slightly from the product purchased All images in this manual are for reference purposes only Parts are not necessarily pictured to scale Product Overview Cont Fig 2 Outd...
Page 10: ...ont Other inclusions not pictured Remote control holder for wall mounting AAA Batteries x2 Instruction manual Installation manual Warranty certificate Installation hardware 11 Power cable 12 Copper nu...
Page 11: ...le Install the unit where it is easy to drain any condensation water Observe the minimum clearances around the unit as stated Fig 4 Check the machine operation regularly and leave the necessary spaces...
Page 12: ...llation diagram Fig 6 Only persons and or companies qualified and experienced in the installation service and repair of refrigerant products should be permitted to do so The purchaser must ensure that...
Page 13: ...y Drill 32mm deep holes in the wall to fix the plate Use a drill bit to fit the 6mm plugs supplied Insert the plastic anchors into the hole Fix the mounting plate by using the provided tapping screws...
Page 14: ...ection must be ensured The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage catego...
Page 15: ...posite directions Fig 12 For R32 refrigerant mechanical connectors should be outdoors Water drainage from the indoor unit The condensed water drainage from the indoor unit is fundamental for the succe...
Page 16: ...onnection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the...
Page 17: ...it for many years to come without loosening The unit must be installed following all relevant local regulations Water drainage from the outdoor unit Condensed water and ice formed in the outdoor unit...
Page 18: ...ith excessive tightening torque there may also be some leakage as the flange could be damaged The best way to tighten the connections is using a fixed wrench and a torque wrench as illustrated in Fig...
Page 19: ...y valve by turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device Turn the body of the 2 way and 3 way valves Disconnect the vacuum pump...
Page 20: ...water can enter Indoor unit test Does the ON OFF switch work properly Do the HEATING COOLING and FAN modes operate normally Do the TIMER ON and TIMER OFF functions operate properly Does each indicato...
Page 21: ...21 After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org Information for the Installer Wiring diagrams Indoor wiring diagram...
Page 22: ...22 After Sales Support 1300 886 649 AUS 0800 836 761 NZ info tempo org Information for the Installer Cont Outdoor wiring diagram...
Page 23: ...1 4 Gas pipe diameter 12mm 1 2 Length of pipe with standard charge 5m Type of refrigerant R32 Max distance between indoor and outdoor unit 15m Additional gas charge 25g m Max difference between level...
Page 24: ...torque for protection caps and flange connection Pipe Diameter Tightening Torque N x m Corresponding Stress using a 20cm wrench Part Tightening Torque N x m 6mm 1 4 15 20 Wrist strength Service port n...
Page 25: ...10 3A Heating 10 2A Power Input Cooling 1190W Heating 1180W Rated Power Input AS NZS 60335 Cooling 2300W Heating 2250W Room size suitability 30 35m2 Rated Voltage and Frequency 220 240V 50Hz Ingress P...
Page 26: ...regulations concerning the disposal of such materials At the end of its working life do not throw this appliance out with your household rubbish Electrical and electronic products contain substances t...
Page 27: ...ill in the details below or in the INSTRUCTION manual so you have them on record should you need to contact the installer in the future Proof of professional installation is also required for warranty...
Page 28: ...ies with the product Product does not work If you encounter problems with this product or if it fails to perform to your expectations make sure to contact our After Sales Support Centre on 1300 886 64...