AJA RH10UC User Manual Download Page 1

 

Revised April 5, 2006

Software Version 2.3

 

RH10UC

 

SD To HD Upconverter

R-series Card Module

 

User Manual

 

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

 

Visit us at www.TestEquipmentDepot.com

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 

Summary of Contents for RH10UC

Page 1: ...er R series Card Module User Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com ...

Page 2: ...to obtain service under this warranty you the Customer must notify AJA Video of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service The Customer shall be responsible for packaging and shipping the defective product to a designated service center nominated by AJA Video with shipping charges prepaid AJA Video shall pay for the return ...

Page 3: ...lack sidebars Full Screen for anamorphic inputs Letterbox input 16 9 letterbox is zoomed to full screen Widezoom a combination of zoom and horizontal stretch to fill 16 9 screen will introduce a small aspect ratio error Separate multipoint H and V filters Motion adaptive interpolation 16 bit coefficients 16 bit internal data paths Accurate 16 bit SD to HD colorspace conversion 1 slot AJA FR1 or FR...

Page 4: ...he PS switch you then use the other switch called Parameter Adjust PA to make a change to the parameter setting Both switches are toggle switches that can be pushed to the right or left allowing you to move forward or backward through available choices After actuation either switch will return to a middle position If you move a switch and hold it in place left or right the RH10UC will sense this a...

Page 5: ...the parameter number Characters 2 through 4 will change to reflect the settings of these parameters as they are incremented decremented Editing Parameters When a parameter has been selected with the PS switch use the PA switch to then change the parameter value as displayed by characters 2 through 4 to another value Like the PS switch you ll move PA switch to the left or right to scroll through th...

Page 6: ...finitions When in Upconvert Mode Parameter Character 1 Definitions Choices are shown in italics 0 Selects a Mode of operation for the board Choices are UP up convert HF high definition framesync 1 Output Format Choices are li 1080i 59 94Hz 7p 720p 59 94Hz A automatic output follows the tri sync input default 2 Upconvert Mode Choices are 43 4x3 pillar box format 14 14x9 pillar box format default FS...

Page 7: ...ges I Information shows current software version W Set RH10UC To Factory Defaults To set all values to factory defaults select Param W and move the adjust switch to the right This will set all parameters in the system to factory values After a 5 second inactivity time out the values will be written to flash If all the values in the system match the factory defaults either through adjustment or by ...

Page 8: ...changes Refer to the H and V Parameter Reference Table that follows for ranges I Information shows current software version W Set RH10UC To Factory Defaults To set all values to factory defaults select Param W and move the adjust switch to the right This will set all parameters in the system to factory values After a 5 second inactivity time out the values will be written to flash If all the value...

Page 9: ... frame How the signal is distributed differs for the FR1 and FR2 frames Additionally individual modules can usually be strapped as to whether external reference is distributed from the frame or directly to BNCs on the module s corresponding cell group the 9 BNCs on the rear panel FR1 Frame the external reference signal is distributed passively to all frame modules If you wish to use the frame refe...

Page 10: ...namorphic 4 3 16 9 or Letterbox 14 9 Wide Zoom 16 9 4 3 4 3 Upconverts To These displays on 16 9 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Visit us at www TestEquipmentDepot com ...

Reviews: