![AIXTRON CRIUS II System Manual Download Page 179](http://html1.mh-extra.com/html/aixtron/crius-ii/crius-ii_system-manual_2883093179.webp)
AIXTRON
- Dokumentation
CONFIDENTIAL
179
6
cr
ius_I
I_e
n_
00,
Ed
it
io
n
06/
201
0
System Manual
Maintenance
CRIUS II
Cooling water system
6.14.2 Cleaning the water filter
Fig. 6-39,
179 shows the water filter.
Fig. 6-39
Water filter
It is not necessary to remove the filter from the pipe line to clean it. Instead,
the filter is cleaned via a manual back washing procedure.
Proceed as follows to clean the water filter:
1
Put a container under the drain (item E) of the filter. You may also con-
nect a hose to the drain as shown in the figure above.
2
Turn the rotary basket (item D) counterclockwise until it is fully open.
This will open the ball valve and rinse the filter.
3
Rinse the filter for 20…25 s
4
To end the cleaning process, turn the rotary knob back to its original
position
5
Check to make sure that no water leaks out of the drain anymore
WARNING!
Harmful substances.
The cooling water circuit contains substances (e.g. biocide) which can
be harmful to your health.
Wear protective gloves and goggles. Dispose cooling water as hazard-
ous waste according to the local regulations.
A Handwheel for pressure adjustment
B Pressure display
C Filter
D Rotary basket
E Drain (with hose)