Button Functions
UP –
Wake thermostat and increase temperature
DOWN –
Wake thermostat and decrease temperature
MODE –
Wake thermostat, change mode
Note:
Hold mode button down for 5 seconds. The thermostat will change from fahrenheit to
celsius or celsius to fahrenheit. The backlight will turn off after five seconds.
INSTALLATION, OPERATION
& APPLICATION GUIDE
HEAT PUMP
9630*351*
9630*353*
Wiring Diagrams
From thermostat 9630*351*, 9630*353*
Green
Gray
Wht/Blk
Fan Hi
Heat Pump
Fan Lo
Y
R
B
W
White
Red
Blue
Yellow
Furnace
+12 VDC
-12 VDC
Compressor
WHP
GH
GL
Caution
This thermostat should be installed by trained technicians only. Adhere to all local and national
codes. Disconnect all power to the system before installing, removing, or cleaning.
Operation
The display indicates the mode and the room temperature. When the mode button is pressed
once, the thermostat will wake and if your thermostat is equipped with a backlight, the backlight
will illuminate. When the mode button is pressed again, the mode will change. Press the or
button to wake the thermostat, the set temperature will display and flash. Press the or
button again to change the set temperature. The thermostat will go back to sleep mode after 5
seconds if no buttons are pressed.
In electric heat mode, if the heat pump is unable to satisfy the thermostat call, the heat pump
will go into lockout (See heat pump and backup heat example for conditions of heat pump
lockout). When thermostat is in lockout, ELEC will flash on the display.
In gas heat mode, the gas furnace will provide the only source of heat and the heat pump is
locked out.
Temperature
Mode
Range
°F
°C
Cooling (set)
33°F to 99°F
1°C to 37°C
Heating (set)
33°F to 99°F
1°C to 37°C
Refer to the operation chart for a more detailed listing of operation sequence.
The thermostat wiring is factory installed by the OEM (Original Equipment Manufacturer). RV
Products suggests the thermostat wiring be a minimum of 18 gauge. The thermostat is intended
for use with a 12 VDC control circuit that does not exceed 1 amp. The thermostat is equipped
with a replaceable 2 amp fuse located on the base of the thermostat. The fuse is designed to
“open” if the circuit is mis-wired or if there is a short in the system. Before replacing the fuse, the
cause of the failure must be located and corrected.
Application
Installation
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by
removing the fuse or switching the appropriate circuit breaker to the Off position
before removing the existing thermostat.
A. THERMOSTAT LOCATION
This thermostat is a sensitive instrument. For accurate temperature control and comfort, the
following considerations should be taken into account:
1. Locate the thermostat on an inside wall about five feet above the floor.
Pick a dry area where air circulation is good.
2. Do not install thermostat where there are unusual heating
conditions, such as direct sunlight, near heat producing
appliances (televisions, radio, wall lamp, etc.), or a furnace or air
conditioner supply register.
B. INSTALLING THE THERMOSTAT
1. Place mounting screw template against the wall where
thermostat will be mounted.
2. Using supplied screws, mount the template to the wall.
3. Remove plastic from between mounting screws.
4. Connect thermostat wiring to motorcoach wiring.
5. Place thermostat on mounting screws and gently push the
thermostat down to lock the thermostat onto mounting screws.
6. Turn on power to the thermostat.
1. Download the
RVClimate app from either the
Google Play store or Apple App store.
2. Open the app and select “
ADD NEW
THERMOSTAT”.
3. On the thermostat, hold the Up and Down
buttons simultaneously to enter pair mode.
4. On the App select “
PAIR NEW
THERMOSTAT”.
5. When prompted, enter the 6 digit ID from the
thermostat and select “
PAIR”.
6. Once connected the thermostat will revert to
the main screen.
7. Slide screen to the left (2nd screen).
8. Press
.
9. Select “
ZONE NAME”.
10. Assign a name or description to the thermostat
(7 characters max).
11. Select “
SET” to save the assigned name or
description.
Note: Each thermostat may be connected
to a maximum of 4 individual phones.
Any subsequent connections will
result in the oldest/first connections being automatically deleted in order.
Pairing additional thermostats
1. Using the
RVClimate app.
2. Slide screen to the left (last screen).
3. Select “
PAIR NEW THERMOSTAT”.
4. On the thermostat, Hold the Up and Down buttons simultaneously to enter pair mode.
5. When prompted, enter the 6 digit ID from the thermostat and select “
PAIR”.
6. Once connected the thermostat will revert to the main screen.
7. Slide screen to the left (2nd screen).
8. Press
.
9. Select “
ZONE NAME”.
10. Assign a name or description to the thermostat (7 characters max).
11. Select “
SET” to save the assigned name or description.
Note: A maximum of 3 units may be added to an individual phone.
Pairing a previously paired thermostat
1. Using the
RVClimate app select “ADD NEW THERMOSTAT”.
2. On the thermostat, Hold the Up and Down buttons simultaneously to enter pair mode
3. Thermostat will automatically pair.
Note: If thermostat doesn’t pair automatically, when prompted enter the 6 digit ID from the
thermostat and select “
PAIR”
.
4. Once pairing is complete, press the thermostat’s mode button to return to the main screen.
Pairing the Thermostat
05-03-18