background image

Button Functions

 

UP –

  Wake thermostat and increase temperature

 

DOWN –

  Wake thermostat and decrease temperature

 

MODE –

  Wake thermostat, change mode

 

Note:

 

Hold mode button down for 5 seconds. The thermostat will change from fahrenheit to 
celsius or celsius to fahrenheit. The backlight will turn off after five seconds.

INSTALLATION, OPERATION 

& APPLICATION GUIDE

HEAT PUMP

9630*351*

9630*353*

Wiring Diagrams

From thermostat 9630*351*, 9630*353*

Green

Gray

Wht/Blk

Fan Hi

Heat Pump

Fan Lo

Y

R

B

W

White

Red
Blue

Yellow

Furnace

+12 VDC

-12 VDC

Compressor

WHP

GH

GL

Caution

This thermostat should be installed by trained technicians only. Adhere to all local and national 
codes. Disconnect all power to the system before installing, removing, or cleaning.

Operation

The display indicates the mode and the room temperature. When the mode button is pressed 
once, the thermostat will wake and if your thermostat is equipped with a backlight, the backlight 
will illuminate. When the mode button is pressed again, the mode will change. Press the   or 

 button to wake the thermostat, the set temperature will display and flash. Press the   or   

button again to change the set temperature. The thermostat will go back to sleep mode after 5 
seconds if no buttons are pressed.

In electric heat mode, if the heat pump is unable to satisfy the thermostat call, the heat pump 
will go into lockout (See heat pump and backup heat example for conditions of heat pump 
lockout). When thermostat is in lockout, ELEC will flash on the display.

In gas heat mode, the gas furnace will provide the only source of heat and the heat pump is 
locked out.

Temperature

Mode

Range

°F

°C

Cooling (set)

33°F to 99°F

1°C to 37°C

Heating (set)

33°F to 99°F

1°C to 37°C

Refer to the operation chart for a more detailed listing of operation sequence.

The thermostat wiring is factory installed by the OEM (Original Equipment Manufacturer). RV 
Products suggests the thermostat wiring be a minimum of 18 gauge. The thermostat is intended 
for use with a 12 VDC control circuit that does not exceed 1 amp. The thermostat is equipped 
with a replaceable 2 amp fuse located on the base of the thermostat. The fuse is designed to 
“open” if the circuit is mis-wired or if there is a short in the system. Before replacing the fuse, the 
cause of the failure must be located and corrected.

Application

Installation

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by 

removing the fuse or switching the appropriate circuit breaker to the Off position 
before removing the existing thermostat.

A. THERMOSTAT LOCATION

This thermostat is a sensitive instrument. For accurate temperature control and comfort, the 
following considerations should be taken into account:
1.  Locate the thermostat on an inside wall about five feet above the floor.  

Pick a dry area where air circulation is good.

2.  Do not install thermostat where there are unusual heating  

conditions, such as direct sunlight, near heat producing  
appliances (televisions, radio, wall lamp, etc.), or a furnace or air  
conditioner supply register.

B. INSTALLING THE THERMOSTAT

1.  Place mounting screw template against the wall where  

thermostat will be mounted.

2.  Using supplied screws, mount the template to the wall.
3.  Remove plastic from between mounting screws.
4.  Connect thermostat wiring to motorcoach wiring.
5.  Place thermostat on mounting screws and gently push the  

thermostat down to lock the thermostat onto mounting screws.

6.  Turn on power to the thermostat.

1.  Download the 

RVClimate app from either the 

Google Play store or Apple App store.

2.  Open the app and select “

ADD NEW 

THERMOSTAT”.

3.  On the thermostat, hold the Up and Down 

buttons simultaneously to enter pair mode.

4.  On the App select “

PAIR NEW 

THERMOSTAT”.

5.  When prompted, enter the 6 digit ID from the 

thermostat and select “

PAIR”.

6.  Once connected the thermostat will revert to 

the main screen.

7.  Slide screen to the left (2nd screen).

8.  Press 

.

9.  Select “

ZONE NAME”. 

10. Assign a name or description to the thermostat 

(7 characters max).

11. Select “

SET” to save the assigned name or 

description.

  Note:  Each thermostat may be connected 

to a maximum of 4 individual phones.  
Any subsequent connections will  
result in the oldest/first connections being automatically deleted in order.

Pairing additional thermostats

1.  Using the 

RVClimate app.

2.  Slide screen to the left (last screen).
3.  Select “

PAIR NEW THERMOSTAT”.

4.  On the thermostat, Hold the Up and Down buttons simultaneously to enter pair mode.
5.  When prompted, enter the 6 digit ID from the thermostat and select “

PAIR”.

6.  Once connected the thermostat will revert to the main screen.

7.  Slide screen to the left (2nd screen).

8.  Press 

.

9.  Select “

ZONE NAME”. 

10. Assign a name or description to the thermostat (7 characters max).

11. Select “

SET” to save the assigned name or description.

 

Note: A maximum of 3 units may be added to an individual phone.

Pairing a previously paired thermostat

1.  Using the 

RVClimate app select “ADD NEW THERMOSTAT”.

2.  On the thermostat, Hold the Up and Down buttons simultaneously to enter pair mode
3.  Thermostat will automatically pair.
  Note:  If thermostat doesn’t pair automatically, when prompted enter the 6 digit ID from the 

thermostat and select “

PAIR”

.

4.  Once pairing is complete, press the thermostat’s mode button to return to the main screen.

Pairing the Thermostat

05-03-18