ELECTRICAL DATA
SM YAZ318 1-A.1 GB
7-1
7.
ELECTRICAL DATA
Power Supply
1 PH, 220-240 VAC, 50Hz
Connected to
Outdoor
Maximum Current
13.7 A
Inrush Current
35 A
Starting Current
10A
Circuit breaker
20A
Power supply wiring no. x cross section
3 X 2.0 mm
2
Interconnecting cable no. x cross section
4 X 1.5 mm
2
(For each IDU)
Note:
•
Inrush current is the current when power is up. (charging the DC capacitors at outdoor unit
controller).
•
Starting current is the current when starting the compressor
NOTE
Power wiring cord should comply with local lows and electrical
regulations requirements.