HEAT PUMP ON THE WATER LOOP
POMPE A CHALEUR SUR BOUCLE D’EAU
WÄRMEPUMPE AN WASSERSCHLEIFE
POMPA DI CALORE SU CIRCUITO DI ACQUA
BOMBA DE CALOR EN CIRCUITO DE AGUA

HRW

019 - 024 - 030

036 - 042 - 048 - 060

5.3kW

R

R

R

R

R

14.6kW

5.7kW

R

R

R

R

R

16kW

Installation  and maintenance manual
Notice d’installation et de maintenance
Installations und Wartungshandbuch
Manuale di  installazione  e di manutanzione
Manual de  instalacion y de mantenimiento

IOM HRW 01-O-3ALL 

-  Part number / Code / code / Codice / Código : 

3990248

Supersedes / Annule et remplace / annulliert und ersezt /
Annulla e sostituisce / anula y sustituye : 

IOM HRW 01-O-2ALL

Summary of Contents for HRW 019

Page 1: ...R R R R 14 6kW 5 7kW R R R R R 16kW Installation and maintenance manual Notice d installation et de maintenance Installations und Wartungshandbuch Manuale di installazione e di manutanzione Manual de...

Page 2: ...INST INSTALLA ALLA ALLA ALLA ALLATION INSTRUCTION TION INSTRUCTION TION INSTRUCTION TION INSTRUCTION TION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES...

Page 3: ...ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS 1 7 1 7 1 7 1 7 1 7 GENERALITIES 17 BMS AND RCL CONTROL MODULES WIRING BMS AND RCL CONTROL MODULES WIRING BMS AND RCL CONTROL MODUL...

Page 4: ...ired electric current of operation taking into account specific conditions of the location and the current required for any other appliance connected with the same circuit The unit must be EARTHED to...

Page 5: ...nges in the weather high and low temperatures Excessively high temperatures above 60 C can harm certain plastic materials and cause permanent damage Moreover the performance of certain electrical or e...

Page 6: ...ER OUTLET 3 4 FEMALE GAS WATER INLET MAIN CIRCUIT BREAKER OPTION ELECTRICAL CONNECTIONS CONDENSATES OUTLET 3 4 A B C 19 24 900 600 439 30 36 1050 660 460 42 48 60 1250 705 513 N P Q R S T U 19 24 65 8...

Page 7: ...mperatures Initial start up and winter operation of the units are guaranteed down to an ambient temperature of 5 C with the return air intake temperature at 5 C and the water inlet temperature at 13 C...

Page 8: ...e rods are attached through the shock mounts to the corners of the unit by suspension angle brackets W W W W Warning arning arning arning arning Do not use rods of a diameter smaller than that stated...

Page 9: ...e canvas connection to be eliminated The duct network must be laid out to avoid any rectilinear runs betweens the heat pump outlet and the air distribution outlets The return air intake ducts can be c...

Page 10: ...CONNECTION FRAME DIMENSIONS AIR BLOWING FRAME AIR BLOWING FRAME AIR BLOWING FRAME AIR BLOWING FRAME AIR BLOWING FRAME RETURN AIR INT RETURN AIR INT RETURN AIR INT RETURN AIR INT RETURN AIR INTAKE FRA...

Page 11: ...ing periods of inoccupation night time setting of the set temperature Each appliance s ventilation system is generally a sub system within the building with its own distribution duct network The simpl...

Page 12: ...ulic pressure surges One of the hose ends must be fitted with a rotating connector to facilitate removal for maintenance Rigid pipes can be connected directly to the unit but this is not recommended d...

Page 13: ...ble to equip the system with a sieve filter sieve filter sieve filter sieve filter sieve filter 0 8 mm on the unit water inlet pipe work This filter should be installed between two isolation valves an...

Page 14: ...e bleed points and the drain taps to empty the system completely The short circuited water supplies and returns must now be connected to the units inlet and outlet connections It is recommended to use...

Page 15: ...20 A Pdc 200 A 9 6A 36 A 24 16A aM Ith 20 A Pdc 200 A 12 8A 46A 10A aM Ith 20 A Pdc 200 A 9 7 A 44 5A 12A aM Ith 20 A Pdc 200A 10 2A 49A 16A aM Ith 20 A Pdc 200 A 14 A 54A 20A aM Ith 20 A Pdc 200 A 1...

Page 16: ...y device CV MV motor condenser K3 K4 K5 MV motor relay depending on version or equipment level W W W W WA A A A ATER CIRCUIT TER CIRCUIT TER CIRCUIT TER CIRCUIT TER CIRCUIT Y1 Water circuit by pass va...

Page 17: ...C HEA ELECTRIC HEATING BA TING BA TING BA TING BA TING BATTER TTER TTER TTER TTERY OPTION Y OPTION Y OPTION Y OPTION Y OPTION EC1 Stage 1 heating elements EC2 Stage 2 heating elements single phase mod...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...nnecting the thermostat wiring V V V V Very important ery important ery important ery important ery important 3N 400V 3N 400V 3N 400V 3N 400V 3N 400V 50Hz 50Hz 50Hz 50Hz 50Hz The outdoor unit is equip...

Page 22: ...r detail of the appliances addressing BMS BMS BMS BMS BMS ST ST ST ST STORM AND MIU ORM AND MIU ORM AND MIU ORM AND MIU ORM AND MIU BMS AND ST BMS AND ST BMS AND ST BMS AND ST BMS AND STORM ORM ORM OR...

Page 23: ...RT located on the appliance J8 Closed the fan is controlled via the compressor and the ICT sensor in Heating mode Open the fan operates continuously in Heating mode except in OFF mode J3 Closed ON OF...

Page 24: ...ions from our sales department an ambient sensor box available as options from our sales department POWER F POWER F POWER F POWER F POWER FAIL AIL AIL AIL AILURE URE URE URE URE In the event of mains...

Page 25: ...nt zones Each zone has its own ON OFF programming as well as customised set temperature settings The programming ON OFF set temperature Mode etc of the zone 0 enables the BMS supervision module to sen...

Page 26: ...unit N 1 is selected press the key on the adapter board until the LED flashes 4 Press the ON OFF key 5 Address N 1 has now been memorised in the first appliance 6 For the second appliance press the ON...

Page 27: ...s valve is installed on the system it limits main circulation pump energy consumption as well as limiting the overall pressure losses in the hydraulic circuit Initially closed the valve opens 30 secon...

Page 28: ...vice versa DEMAND FOR COOLING DEMAND FOR COOLING DEMAND FOR COOLING DEMAND FOR COOLING DEMAND FOR COOLING 1 With the MODE key on the RCL control module select COOL mode and then set the minimum temper...

Page 29: ...other should be situated at a normal level in order to ensure the unit s correct and normal operation 2 Ensure that the thermostat is connected properly and set the set temperature above the ambient...

Page 30: ...MAINS POWER SUPPL T THE MAINS POWER SUPPLY IS OFF Y IS OFF Y IS OFF Y IS OFF Y IS OFF AND THA AND THA AND THA AND THA AND THAT THERE IS NO POSSIBILITY OF IT BEING A T THERE IS NO POSSIBILITY OF IT BEI...

Page 31: ...Check that air is not being sucked into the hydraulic system Bleed the system if required APPEARANCE OF W APPEARANCE OF W APPEARANCE OF W APPEARANCE OF W APPEARANCE OF WA A A A ATER DROPLETS IN THE AP...

Page 32: ...perature at the level of the loop Insufficient water flow Test the water flow at the level of the main loop Insufficient airflow Test fan operation and pressure losses on the air intake duct network C...

Page 33: ...mperature 30 C Test the temperature at the level of the main loop Insufficient water flow Test the water flow at the level of the main loop The float is not properly connected to the PCB broken wire C...

Page 34: ...r should include part name part number model number and serial number of the unit involved Following our personal inspection of the returned part and if it is determined that the failure is due to fau...

Page 35: ...5 ADELAIDE Offices on the Park Suite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE...