Airwell ECF 11 A RC Installation Manual Download Page 1

GB

INSTALLATION MANUAL  4521042/01

Comfort Range

Comfort Range

Read these instructions carefully before starting installation and keep them safely for future reference

CE

Heat pump

Remote control RC4

Cassette model 1 1

Cassette model 16

Cassette model 18

Cassette model 24

Air Conditioning

Air Conditioning

Cooling only

K INST. MENU

Summary of Contents for ECF 11 A RC

Page 1: ...d these instructions carefully before starting installation and keep them safely for future reference CE Heat pump Remote control RC4 Cassette model 1 1 Cassette model 16 Cassette model 18 Cassette mo...

Page 2: ...ensate evacuation 16 5 2 Hydraulic connections 16 6 ELECTRICAL CONNECTION 6 1 Electrical Connection 18 6 2 Electric heating 19 6 3 Fault warning repeater 19 6 4 Cooling only 230V 50Hz 21 7 AIR DISTRIB...

Page 3: ...ssettes Unit model Ref commerciale Manual ref Cassette model 11 K12RCC 1 1 Cassette model 15 K16RCC 1 6 Cassette model 18 K18RCC 1 8 Cassette model 24 K24RCC 2 4 Model cross reference details K INST M...

Page 4: ...the national legislation transposing them Machines Directive 98 37 ECC Low tension Directive DBT 73 23 EEC Electromagnetic compatibility Directive 89 336 EEC and that the following paragraphs of the...

Page 5: ...trical supply to the unit Take care It is forbidden to start any work on the electrical components if water or high humidity is present on the installation site Take care When the unit is being connec...

Page 6: ...s Fascia clips 1 Documentation bag 1 Fascia assembly 1 Remote control 2 2 CASSETTE DIMENSIONS 1 Suspended ceiling 2 T bar suspended ceiling 3 Evaporator 4 Fan 5 Intake grille 6 Electrical connection 7...

Page 7: ...Description suite 2 2 4 DIMENSION OF OUTDOOR UNIT 11 16 760 544 472 58 48 220 236 260 88 5 58 WIRING CONNECTIONS SUCTION TUBE FLARED LIQUID TUBE FLARED VALVE CONNECTIONS AIR INTAKE AIR OUTLET 237 50...

Page 8: ...8 Cassettes 2 2 4 DIMENSION OF OUTDOOR UNIT 18 24 Description continued 300 325 370 WIRING CONNECTIONS 103 90 75 AIR OUTLET AIR INTAKE 330 50 843 690 545 490 302 350 151 5 151 5 K INST MENU...

Page 9: ...20 3G 2 5 1 5G 1 5 SCROLL compressor Power supply by cassette Powersupply by Outdoor unit TYPE OFAPPLIANCE 18 24 1 230 V 50 Hz COOLING VENTILATION ORHEATPUMP HEATING Nominal current Cooling ventilati...

Page 10: ...cassette Powersupply by Outdoor unit TYPE OFAPPLIANCE 18 24 1 230 V 50 Hz COOLING VENTILATION ORHEATPUMP HEATING Cooling ventilation A 4 4 5 4 Maximumcurrent FuseratingaM FuseratingASE VDE Cable secti...

Page 11: ...re not to exeed 12 meters LENGTH OF THE LINKINGS PIPES MAXIMUM HEIGHT OF THE COOLING LINK The maximum permissible difference in height between the outdoor unit and the indoor unit is indicated see bel...

Page 12: ...acking on the delivery note is not sufficient for the shipper s insurance company IIt is recommended to place the cassette as near as possi ble to the final installation site before unpacking Avoid pl...

Page 13: ...set the switches as follows and then reset the remote control Refer to the remote control manual 4 1 USAGE CONFIGURATION To change the configuration from HEAT PUMP to STAN DARD On the electronic circ...

Page 14: ...suspended ceiling with panels dimensions of 60 x 60 cm or multiples thereof Installing the cassette will be easier with the use of a fork lift truck Use the packing base by placing it between the cass...

Page 15: ...covered inside with an insulating material 12 to 25 mm thick glass fibre When the installation is finished all the surfaces of the non insulated ducts must be covered with anti condensa tion insulati...

Page 16: ...rated below Connections 5 1 CONDENSATE EVACUATION To ensure effective condensate evacuation the downward slope must be 1 cm per metre without any restricted or ascending section The condensate extract...

Page 17: ...designed to be connected to the outdoor units using flare lines refrigerant grade copper pipe fitted at both ends with flare nuts and insulated over the full length PIPE PREPARATION Use refrigerant gr...

Page 18: ...d their representatives decline all responsibility for any accidents caused by inadequate or non existent earthing of the installation All the cassettes are intended to operate on a normal vol tage of...

Page 19: ...lly the another is automatically reset They cut off electrical supply to the heating resistance as soon as an operating anomaly is detected Manual reset Valves 6 3 FAULT WARNING REPEATER When the uppe...

Page 20: ...cation Manufacturing changes can lead to modifications Always refer to the diagram supplied with the product Electrical connection continued B K B l a c k B N B r o w n B U B l u e G N Y E Green Yello...

Page 21: ...od 11 Mod 15 Mod 17 Mod 18 Mod 24 Mod 11 Mod 15 Mod 17 6 6 4 Cooling only 230V 50Hz Electrical connection continued N L 6 5 4 3 N 6 5 4 N L Mod 11 Mod 15 Mod 11 Mod 15 230V 50HZ Mod 17 Mod 17 ONG Repl...

Page 22: ...place the sensor wire by dummy sensor 4 7k Sensor wire coming from the cassette 400V N L 6 5 4 3 N 6 5 4 N L3 L2 L3 3N 400V Mod 18 Mod 24 Mod 18 Mod 24 L1 L2 L1 N L 6 5 4 3 N 6 5 4 N L3 L2 L3 3N 400V...

Page 23: ...s less than 5 mm A B A B 7 7 1 AIR DISTRIBUTION MODULE FITTING Carefully unpack the module and fit the clips in the frame corners Display 5 m m A Avoid bending the frame with excessive pulling The fra...

Page 24: ...rall cleanliness of the installation and check that the condensate evacuation is not blocked particularly that of the evaporator coil Check the condition of the condensate tray A dirty filter creates...

Page 25: ...fices on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3 19 Dar...