Airtecnics Kleenbox
46/46 Installation, Operation And Maintenance Manual Download Page 10

10 

MAINTENANCE INSTRUCTIONS 

 

 

For safety, before cleaning, turn off the appliance using the controller. 

 

It is forbidden to open the service panel (risk of electric shock and trapping in 
fans). 
Repairs must be carried out exclusively by authorized personnel. 

 

The inside of the appliance must not be cleaned with water or steam.

 

Exterior cleaning 

The Kleenbox HEPA filtration boxes do  not need any kind  of maintenance, except the housing cleaning for 
the vertical models. 

It  is  recommended  to  clean  the  inlet  grille  once  a  month.  To  do  that,  is  very  important  to  shut  down  the 
equipment. If it keeps running, the fan could hover the wet dust causing damage to the rotor and covering the 
filters, reducing its lifetime. 

Cleaning the body of the purifier should be done with a damp cloth and a conventional detergent. Do not use 
caustic or acid-containing detergents. 

                         

 

Internal cleaning 

In models with perforated grille, it is advisable to clean the inside of the unit with a vacuum cleaner at least 
once every 2 years (*), better to do it before winter, using qualified personnel. 
It is recommended to clean the inside of the equipment frequently with the help of a vacuum cleaner. (*) 

(*)  These  periods  are  indicative  depending  on  the  conditions  of  each  installation.  In  places  with  a  high 
number of suspended particles it is desirable to increase the frequency of interior cleaning. 
 
 

REPAIRS AND REEMPLACEMENTS 

 

 

The assembly and the electrical connection must be carried out exclusively by specialized 
personnel and observing these instructions. 
Before carrying out any repairs, you must: 

 

Notify staff and indicate that work is in progress. 

 

Disconnect the power and protect the termal magnet (so that no one can 
accidentally actuate it). 

 

Make sure there is no voltage on the purifier. 

 

Make sure that the fans have stopped. 

 

Use only original spare parts. 

 

Summary of Contents for Kleenbox 46/46

Page 1: ...e installation Give this manual to the end user SECURITY ADVISE SYMBOLS WELDOM20110 R0 24 02 21 Attention Danger Safety Warning High voltage or electric current hazard Danger of injury Attention Do no...

Page 2: ...UCTIONS 4 Control board features 4 WIRING DIAGRAMS 4 TECHNICAL DATA 6 MAINTENANCE INSTRUCTIONS 10 Exterior cleaning 10 Internal cleaning 10 REPAIRS AND REEMPLACEMENTS 10 Filter reemplacements 11 Fan r...

Page 3: ...ower and control and necessary fixings are external on the lateral of the equipment The equipment has a service panel to carry out repairs and replacements see REPAIRS section Power supply HORIZONTAL...

Page 4: ...ts If the packaging is open cover the purifier to protect it from dust Do not step on or place heavy load son it to avoid damage to he material Storage temperatura between 20 C and 40 C When transport...

Page 5: ...5...

Page 6: ...6 TECHNICAL DATA...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...t use caustic or acid containing detergents Internal cleaning In models with perforated grille it is advisable to clean the inside of the unit with a vacuum cleaner at least once every 2 years better...

Page 11: ...hey are opened take off the panel using the handle Filter reemplacements Both models include a visual dirty filter alarm When the led is turned ON the H14 HEPA filter must be changed the lifetime of H...

Page 12: ...space to take off the H14 filter This one is fixed to the housing by four wing nuts that should be untighten before remove the filter HEPA H14 Filter To place the filters inside the equipment follow...

Page 13: ...rs to get more working space and avoid damages to them Straightaway disconnect the fan wires Depending on the model we have Kleenbox Horizontal Power supply black box faston 0 10V regulation white box...

Page 14: ...tion It has four hexagonal screws To assemble the new fan follow the same steps in reverse order ACCESSORIES Optional accessories not included for the Kleenbox installation Protection panel for HEPA f...

Page 15: ...15 DECLARATION OF CONFORMITY...

Page 16: ...that eventually suffer failures attributable to production defects Installation costs are borne by the buyer Products that in our opinion have been used improperly handled incorrectly improperly inst...

Reviews: