Airtecnics DIF-PUR 6/12 Installation, Operation And Maintenance Manual Download Page 13

(13) 

 Air purification unit 

 Dif-Pur 

IDENTIFICACIÓN DEL EQUIPO 

 
All  DIF-PUR  are  identified  by  a  unique  serial  number  printed  on  a 
label  located  on  the  outside  of the  equipment.  It  also  indicates  the 
model  and  its  most  important  technical  characteristics  (voltage, 
intensity, power, etc.) 
 
It is essential to have this number to provide possible spare parts or 
technical information of the equipment in question. 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARRANTY 

 
Our warranty extends for one calendar year from the date of delivery.  The warranty is limited to repairing or 
replacing  products  that  may  suffer  faults  that  may  be  blamed  on  production  defects  from  our  warehouse. 
Installation costs are borne by the buyer. Products that we believe have been misused, improperly handled, 
improperly  installed,  connected  to  voltages  other  than  the  nominal,  modified  or  repaired  by  unauthorized 
personnel or damaged during transport, are excluded from any warranty. 
 

For  the  validity  of  this  warranty,  it  will  be  essential  that  it  is  properly  filled  in  and  accompanied  by  the  invoice  proving  the  date  of 
purchase. If manipulated, it will lose its validity. 
It is the sole responsibility of the exclusive buyer to seek the necessary safety measures so that in case of breakdown of one of our 
products there is no damage to third-party equipment, facilities, or individuals. 

 

 

Warranty sheet

 

 

Equipment data: 
 
Model: ...............................................                   Serial number

.............................................................

 

 

Invoice date

: ....................................             

    Invoice number:

 

......................................................            

 

Buyer data: 

 

Name: 

.................................................................................................................................................. 

 
Adress: ........................................................................................................................................................... 
 
Country

: …………………………   Telephone: .........................................    Fax: ........................................... 

 
Seller data: 

 

Name

: .................................................................................................................................................. 

 
Adress: ........................................................................................................................................................... 
 
Country

: …………………………   Telephone: .........................................    Fax: ………………………………. 

 
 

Signature and stamp of the buyer 

 

 

 Signature and stamp of the seller 

Summary of Contents for DIF-PUR 6/12

Page 1: ...ns carefully before attempting installation Deliver this manual to the final user SEGURITY ADVISE SYMBOLS Attention Danger Safety Advice Danger from electric current or high voltage Injuries risk Dang...

Page 2: ...ntrol 3 Fixations 4 STORAGE AND TRANSPORT 4 OPERATING INSTRUCTIONS 5 Controllers characteristics 5 WIRING DIAGRAM 5 TECHNICAL SPECIFICATIONS 7 MAINTENANCE INSTRUCTIONS 9 REPAIRS AND REPLACEMENTS 9 Fil...

Page 3: ...nance must be carried out exclusively by qualified personnel observing these instructions and in accordance with applicable standards In case of providing special control a specific manual is attached...

Page 4: ...t has 6 M8 threaded anchors STORAGE AND TRANSPORT Attention Heavy product Do not place under the suspended appliance during transport or assembly Store in a dry and weatherproof place If the packaging...

Page 5: ...aracteristics ON OFF They have a switch that cuts off the fan power and automatically stops the equipment Control 0 100 They include a potentiometer 0 10V that allows to regulate the fan speed from 0...

Page 6: ...6 Air purification unit Dif Pur...

Page 7: ...7 Air purification unit Dif Pur TECHNICAL SPECIFICATIONS...

Page 8: ...8 Air purification unit Dif Pur...

Page 9: ...the equipment must be carried out exclusively by authorized personnel It is forbidden to open the service panel without disconnecting the power risk of electric shock and fan entrapment The inside of...

Page 10: ...Finally remove the dirty filter and place the new one by following the steps in reverse order In the case of the prefilter it is not necessary to remove the inlet grille since the filter is located on...

Page 11: ...be supported by its own hose cable The next step is to remove the drive fence and absolute filter as set out in the previous points Before separating the fan from the bracket the cables must be discon...

Page 12: ...12 Air purification unit Dif Pur DECLARATION OF CONFORMITY...

Page 13: ...ucts that we believe have been misused improperly handled improperly installed connected to voltages other than the nominal modified or repaired by unauthorized personnel or damaged during transport a...

Reviews: