UT150SC/B 

Installation and Wiring Instructions 

 
 
 
 

All  wiring  to  be  in  accordance  with  the  current  I.E.E. 
Regulations, or the appropriate standards of your country and 

MUST 

be installed by a suitably qualified person. 

The  Fan  should  be  provided  with  a  local  isolator  switch 
capable  of  disconnecting  all  poles,  having  a  contact 
separation of at least 3mm. 
Ensure  that  the  mains  supply  (Voltage,  Frequency,  and 
Phase) complies with the rating label. 
The  Fan  should  only  be  used  in  conjunction  with  the 
appropriate Airtech products. 
The fan should only be used in conjunction with fixed wiring. 
When the Fan is used to remove air from a room containing a 
fuel-burning  appliance,  ensure  that  the  air  replacement  is 
adequate for both the fan and the fuel-burning appliance. 
The Fan should not be used where it is liable to be subject to 
direct water spray for prolonged periods of time. 
Where ducted Fans are used to handle moisture-laden air, a 
condensation trap should be fitted. Horizontal ducts should be 
arranged to slope slightly downwards away from the Fan. 
This appliance is not intended for use by persons (including 
children)  with  reduced  physical,  sensory  or  mental 
capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety. 
Young children should be supervised to ensure that they do 
not play with the appliance. 

This product should not be disposed of with household waste.  Please recycle where facilities exist.  Check with 
your local authority for recycling advice. 

IP65 

SAFETY AND GUIDANCE NOTES 