142938999-1
Installation
Manual
Software from Version: V6.0
ADVISOR
®
CD 7212
CD95/15012
All manuals and user guides at all-guides.com
all-guides.com
Page 1: ...142938999 1 Installation Manual Software from Version V6 0 ADVISOR CD 7212 CD95 15012 All manuals and user guides at all guides com a l l g u i d e s c o m...
Page 2: ...en permission of SLC BV DISCLAIMER SLC BV makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for...
Page 3: ...and programming information Programming The Programming Manual for the CD72 or the CD95 CD150 covers all necessary aspects of programming the system Everybody involved in installing or maintaining thi...
Page 4: ...Page 4 Installation manual for CD72 95 15012 All manuals and user guides at all guides com...
Page 5: ...g CD3008 CD3048 keypad 18 Figure 10 Opening the CD3008 CD3048 keypad 18 Opening CD3009 CD3049 keypad 18 Figure 11 Opening the CD3009 CD3049 keypad 18 CD3008 CD3009 keypad 19 Figure 12 CD3008 CD3009 ke...
Page 6: ...394 internal siren AS256 27 Figure 23 Connecting the AS294 394 27 Connecting the GS600 610 710 711 shock sensor CD72 only 28 Figure 24 Connecting the GS710 711 with separate alarm tamper loops 28 Figu...
Page 7: ...ays must NOT be fitted inside the control panel cabinet The switching of these relays may cause electrical interference 4 1 Use a relay with good insulation between the contacts and the coil 4 2 Place...
Page 8: ...together in one zone The zone has two end loop resistors 4 7 kOhm to differentiate between alarm and tamper Figure 2 shows how they are connected Program the zones menu as Dual Figure 2 Joint Connecti...
Page 9: ...e 6 Expander 2 1 2 3 4 ON SD Remote 7 1 2 3 4 ON SD Remote 8 CD95 150 CD72 1 2 3 4 ON SD Expander 9 1 2 3 4 ON SD Expander 10 1 2 3 4 ON SD Expander 11 1 2 3 4 ON SD Expander 12 CD95 150 only 1 2 3 4...
Page 10: ...When the connection with the short circuit is removed the power supply will return to 12 volts NOTE ONLY KEYPAD ONE IS OPERATIONAL Every time power is removed from the system the control panel memoris...
Page 11: ...g keys may be used Always enter a 0 before entering an engineer user code to prevent errors Under keys 1 to 9 there are 3 letters of the alphabet press the keys repeatedly to enter first the number th...
Page 12: ...wn use procedure 2 if not then replacement of the PCB is the only way to gain access to programming mode 2 By programming Use this method if Engineers Lock blocking is active and the engineers code is...
Page 13: ...isplayed c Press accept DIALLER The use of the RD6203 dialler is recommended This dialler fits inside the control panel cabinet and is connected to the control panel s PCB using the cable supplied The...
Page 14: ...Power supply adjustment DO NOT ADJUST Printer connector Fixing hole Fixing hole Fixing hole Cable entries BATTERY 230V connection Transformer Main PCB Main PCB RD6203 Dialler To hold lid in place whil...
Page 15: ...41 42 43 1 2 3 4 5 Battery 18VAC To RD6203 Eprom Processor EEprom JP1 Tamper switch external tampering Ext Siren Tamper Line Fault to keypads and expanders Outputs PL1 RS232 printer External siren O...
Page 16: ...Printer connector RS232 Fold lid down CD95 Figure 7 CD95 cabinet Power supply adjustment DO NOT ADJUST Fixing hole Dialler connector Memory card selector Dialler connector Output expander socket Prin...
Page 17: ...ter RS232 External siren O put 50 Internal siren O put 49 CD9503 CD15003 Zones 1 16 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 FTC Reset in 39 40 41 42 43 44 45 46 Outputs 1 8 9 10 11 12 13 14 15 16 1 2 3...
Page 18: ...8 CD3048 KEYPAD Figure 10 Opening the CD3008 CD3048 keypad OPENING CD3009 CD3049 KEYPAD Figure 11 Opening the CD3009 CD3049 keypad Push Push clip in with screwdriver and lift up cover Remove screw if...
Page 19: ...e 12 CD3008 CD3009 keypad CD3048 CD3049 KEYPAD Display contrast adjustment Keypad address setting switches Cable entry from top Fixing hole Push side clip to remove PCB Cable entry from back Cable ent...
Page 20: ...hout lid tamper Link 2 3 Expander Address setting switches Cable entry from back Cable entry from bottom Reverse tampering Zones Outputs Four wire bus connection Cover tampering Processor A C B D OA O...
Page 21: ...x base When the keypad lid is not used remove the hinge slot blanking pieces from the base and place them in the hinge slot openings For back tamper protection fix the screw through the hole into the...
Page 22: ...WAYS INTERCONNECT NEGATIVES OF POWER SUPPLIES A B C D 4 wire bus Central power supply A B C D 4 wire bus of keypad or expander 4 1 D E BU4 4K7 4K7 To Power Monitor zone CD72 95 150 Auxiliary power sup...
Page 23: ...loop Connecting a detector without memory CONNECTING A DETECTOR WITH LATCH Power supply Input zone Output Latch Output Walk test M W S S A A 4k7 4k7 1 2 3 4 5 6 7 8 9 10 Figure 17 Dual loop Connectin...
Page 24: ...12V Output Arm Disarm Output System Clear 4k7 4k7 Programme outputs for negative applied Figure 18 Connecting a key switch with LED s CONNECTING A NITEWATCH SYSTEM CP 4005 Light zone 1 Light zone 2 Da...
Page 25: ...nal 5 of the RC213 relay OR To terminal of the panel O1 Fire reset O2 External siren O3 Fire Figure 20 Connecting a fire detector Note 1 If there are several detectors place them in parallel and cable...
Page 26: ...OB OA OB OA OB OA OB OA OB CD150 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Table 3 Numbering of the outputs NB In a keypad OA is the buzzer OB does not exist in a CD3008 CD3009 keypad CONNECTING...
Page 27: ...trol 01 Int Sir Sy 01 Int Sir Sy Internal siren control 18 Int Sir Sy 49 Int Sir Sy External siren control 19 Ext Sir Sy 50 Ext Sir Sy Table 4 Programming for the sirens NB If the tampers must be plac...
Page 28: ...15012 CONNECTING THE GS600 610 710 711 SHOCK SENSOR CD72 ONLY Figure 24 Connecting the GS710 711 with separate alarm tamper loops Figure 25 Connecting the GS710 711 with combined alarm tamper loops Al...
Page 29: ...stallation manual for the CD72 95 15012 Page 29 PRINTER OUTPUT PL1 CD72 PL4 CD95 150 PL1 CD72 PL4 CD95 150 DB25 RS232 DB9 RS232 Figure 26 Printer connection All manuals and user guides at all guides c...
Page 30: ...Programming Output Panel AS270 AS271 Description Output connection CD72 1 Tamper terminal 30 2 Tamper terminal 31 3 12V terminal 11 4 0V Internal siren 18 Internal siren terminal 10 5 0V Flash Beacon...
Page 31: ...Expander output 800 mA 20x5 230 VAC Battery secondary fuse 315 mA 12 Vdc 16 Ah maximum for CD 72 12 Vdc 24 Ah maximum for CD 95 150 Max current consumption Power consumption CD 72 CD 95 150 CD 3008 30...
Page 32: ...5 control panel 100 mA 1 to 8 6 to 17 remotes 40 mA 9 to 24 18 internal siren CD72 1A n a 19 external siren CD72 1A n a Table 5 Overview of the inputs and outputs on the CD72 Output no Location Output...
Page 33: ...P CD7212 Note The quick code numbers in front of each menu item i e 2 4 4 to jump to Digi Cutout are also the section heading numbers in the Menu Contents chapter of the programming manual where the i...
Page 34: ...Page 34 Installation manual for the CD72 95 15012 All manuals and user guides at all guides com...
Page 35: ...Installation manual for the CD72 95 15012 Page 35 All manuals and user guides at all guides com...
Page 36: ...Page 36 Installation manual for the CD72 95 15012 All manuals and user guides at all guides com a l l g u i d e s c o m...
Page 37: ...CD95 15012 Note The quick code numbers in front of each menu item i e 2 4 4 to jump to Digi Cutout are also the section heading numbers in the Menu Contents chapter of the programming manual where the...
Page 38: ...Page 38 Installation manual for the CD72 95 15012 All manuals and user guides at all guides com...
Page 39: ...Installation manual for the CD72 95 15012 Page 39 All manuals and user guides at all guides com...
Page 40: ...Page 40 Installation manual for the CD72 95 15012 All manuals and user guides at all guides com...