page 36
- CYPRES 2 User’s Guide -
meters). This is achieved through a water-resistant
casing, sealed plug connections, a sealed cutter, a
sealed
control unit, and a special filter. The filter al
-
lows precise measurement of the air pressure and at
the same time keeps water away from the inside of
the unit. As long as there is no contact with water,
the filter never needs to be replaced by the user.
After water contact, the unit must be switched
off immediately after exiting the water. The filter
must be replaced before next use. Do not leave the
CYPRES / Filter in a wet condition over a long pe-
riod of time. After a water jump, dry the CYPRES
unit separately from the wet parachute and replace
the filter in a timely manner.
The CYPRES 2
filter changer tool is made from
stainless steel, specifically for the purpose of filter
removal and replacement. Filter replacement (see
Section 4.7) can be done by your rigger (packer).
After water contact, the rig and the reserve must
be dried according to the manufacturer’s instruc-
tions. After that the rig and CYPRES 2 with the
new filter can be used again.
4.6 CYPRES 2 and Water jumps
CYPRES 2 allows water jumps without removal of
the unit. CYPRES 2 is waterproof for a duration of
up to 24 hours down to a water depth of 8 feet (2.5
Summary of Contents for Expert CYPRES 2
Page 1: ...User Guide CYPRES 2 User s Guide english version CYPRES 2 Reliability made in Germany...
Page 64: ...CYPRES 2 User s Guide page 63 Personal Info...
Page 65: ...In case someone from the security personnel has concerns...
Page 66: ......
Page 67: ......
Page 69: ......
Page 70: ......
Page 72: ...This page intentionally left blank...