20
RO Inline™ 300 RO Inline™ 500
RO Plus™ l
RO Plus™ ll
RO Plus™ lll
RO Basic™
Water capacity, up to, l/h
at 15 °C/3 bar or 59 °F/44 psi supply pressure
300
600
900
90 at 3 bar / 44 psi
180 at 7 bar / 102 psi
300
500
Membranes, pce
1
2
3
1
1
2
Power supply V AC
230/240 V, 50/60 Hz is always 1P+N+PE
3x400/230 to 480/240 V, 16 Amp
3P + N + PE
230V, 13 Amp
1P + N + PE
230V, 13 Amp
1P + N + PE
Operating voltage range V AC
± 10 %
± 10 %
± 10 %
Frequency Hz
60 Hz is non standard
50/60
50/60
50/60
Membrane pressure pump kw
1,5
-
0,75
Booster supply pump kw
0,5
0,5
-
Max. effect kw
2,0
0,5
-
Supply water pressure bar/psi
2-7 / 29-101,5
3-7 / 43,5-101,5
2-7 / 29-101,5
Supply water connection
3/4”
3/4”
3/4”
Membrane operating pressure range bar
10 - 13 (max. 15)
3 - 7 (max. 7)
10 - 13 (max. 15)
Alarm out, potential free
Stabilized salt rejection.
with 2000 mg/l NaCl at 25 °C/10 bar
Up to 98%
Up to 98%
Up to 98%
Vessel pressure range, bar
-
-
2 to 6 (default 2 to 5)
Hysteresis range
-
-
1 - 4 (default 3) bar
Outlet pressure bar
1,5 - 3,5
1,5 - 3,5
Min. vessel pressure - 1
Drain flush - with softener
- without softener up to 15 °dH
> 30 %
> 50 %
> 30 %
> 50 %
> 30 %
> 50 %
Temp. range °C/°F
1-20 (35) / 34-68 (95)
1-20 (35) / 34-68
1-20 (35) / 34-68
Noice level dB (A)
< 70
< 70
< 70
Dimensions (width x depth x height)
720 x 600 x 1835 mm
28,5” x 23,6” x 72,3”
510 x 400 x 1650 mm
20,0” x 15,8” x 65,0”
incl. 200 mm / 8” elevation
695 x 380 x 1255
mm
27,4” x 15,0” x 49,4”
845 x 380 x
1255mm
33,3” x 15,0” x 49,4”
Weight kg/lbs
Weight incl. water in vessel kg/lbs
182 / 401
-
193 / 426
-
240 / 529
-
32 / 71
-
69 / 52
89 / 196
86 / 190
106 / 234
Protection class IP
53
53
52
Water tank incl. base
Volume, l
125
300
600
125
Dimensions (width x depth x height) mm
570 x 570 x 1100
22,5” x 22,5” x 44”
750 x 750 x 1200
29,5” x 29,5” x 47,3”
750 x 750 x 1800
29,5” x 29,5” x 71”
570 x 570 x 1100
22,5” x 22,5” x 44”
Weight, kg
14
25
37
14
Temperature range °C/°F
1-20 (35) / 34-68 (95)
1-20 (35) / 34-68 (95)
4.6