4 Installation of AirSpeed 1050 B3
AirSpeed 1050 B3 is installed on a pole. Prior to installation of the AirSpeed unit a mounting arm (not
supplied) must first be affixed in place on the Pole.
Caution:
Proper local rigging and hoisting practices should be followed when installing the AirSpeed
1050 B3.
Note:
When installing the unit, a minimum gap of at least 35cm above the unit (so as to NOT block
airflow) and a minimum gap of 20cm below the unit should be kept. In the event of any heat radiating
source below the unit widen the gap.
Recommended:
When installing the unit, care should be taken so that the unit should be distanced
from any obstructions above
that can interfere with “clear sky” conditions needed for good GPS
reception. It is recommended to install the unit in a location which enable GPS reception from at least
four satellites (can be tested with general mobile application).
In the event this is unavoidable there is the option to use a remote GPS installation using an external
antenna.
Note:
There should be no other devices mounted on either side of the unit so as NOT to interfere
with the antennas.
Note:
Installation should take into consideration the antenna(s) and Sector(s) direction for maximum
coverage.
Note:
Installation should be so the antenna(s) are positioned as shown below for maximum coverage.