AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186
Airspan Commercial and Internal Use
49
Figure 43: Slide over and click
Note:
The shell should be hand tightened only. Do NOT use tools to tighten the shell.
Once the connector is properly installed, the cable should be positioned and secured to minimize
stress on the cable and connector.
5.5
Connecting the AC Power Cable to AirHarmony-4400
Danger:
Hazardous voltage! Before working, ensure that the power is removed from the
power connection cables. When the system is powered on,
do not touch the power
terminals
.
5.5.1
Power Cable Preparation
Tip:
It is good practice to label both ends of the cable to identify which AirHarmony-4400
unit it is connected to.
Tip:
It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow
for easier wiring and will allow the cable to be re-terminated if necessary in the future.
Warning:
Required - circuit breaker for AC power source -16A for EU installation and 20A
for US installation. Minimum – 10A.
The power cable is connected to the AirHarmony-4400 connector (marked PWR) on the bottom
panel of the unit.
1.
Prepare the connector by unscrewing the body pf the AC connector, included in the
AirHarmony-4400 package.
Figure 44: AC connector