AirHarmony-4000 DC (Integrated External Duplexers) Installation Guide
UGD-D01123
Airspan Commercial and Internal Use
26
Caution:
Proper local rigging and hoisting practices should be followed when installing
the AirHarmony-4000.
4.2.1
Mounting on a Wooden Pole
The following images show the pole mount assembly on a wooden pole.
Caution:
Take care to install the Pole/Wall mounting plate in the correct orientation.
Verify that the mounting pins are facing upwards as shown below.
Figure 7: Pole/Wall mounting plate
1.
Select the location on the pole to mount the AirHarmony-4000. You can attach the
AirHarmony-4000 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter.
2.
Determine where to position the mounting plate on the pole and mark where to drill for
insertion of the 3/8-16 through-bolt.
Note:
Threaded rod and necessary hardware are not supplied by Airspan and are the
responsibility of the installer.