Air4G Installation Guide
Page 66
Commercial in Confidence
UGD-D00229 Rev B
9 Appendix A
9.1 Review Job Sheet
The
Job Sheet
should include the following information:
BS location and identity.
Whether the system is required to be locked to a GPS timing reference.
A BSID is required for each BS
. This should be in a format xxxxxx:xxxxxx where x
is a decimal digit.
Network configuration information for the BS TRx.
Traffic Port:
Not applicable.
IP Address:
Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Netmask:
Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Default Gateway:
Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
Management VLAN:
Specified as either Untagged or Tagged
Management VLAN Tag:
Should only be set if Management VLAN is set to Tagged
Management IP Mode:
Specified as Static IP Address or Obtain IP Address via DHCP
Ethernet Mode:
Specified as Auto-negotiate or Fixed
Ethernet Rate:
Need only be configured if Ethernet Mode is set to Fixed, specified as
10M or 100M.
Ethernet Duplex:
Need only be configured if Ethernet Mode is set to Fixed, specified as
Full or Half.
SNMP configuration information
. This will allow events from the BS to arrive at the
specified Netspan server. This will include the following information:
Read Only Community
: This should be specified to the same value as in Netspan
Discovery Parameters (found under Server on Netspan left hand panel).
Read Write Community
: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
SNMP Port Number
: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
IP Address:
This specifies Netspan IP address (found under Server Global
Configuration, which is under Server on Netspan left hand panel).
Community:
Normally specified to the same value as for Read Only Community.
Port Number:
Normally specified to a value of 9023.
NTP configuration
. This specifies a list of NTP servers.
9.2 Securing Fiber-optic Cable
The Milli-Tie can be used to secure cables in the same manner as normally used for nylon straps.
The steps below show the basic use of the product.
Caution:
Over-tightening of cable ties may causes damage and degrade system
performance.
To secure fiber-optic cables, perform the following steps:
1. Place the Millie-Tie around the target, and thread the tongue through the last large
aperture in the rearmost cell.