Air4G Installation Guide
Page 51
Commercial in Confidence
UGD-D00229 Rev B
1. Position the external Duplexer above the area where the Air4G will be attached. Verify
that the distance between the external Duplexer is well within the length of the provided
RF jumper cables, i.e. 1.5 meters or less.
2. Feed the band through the provided slits on the pre-assembled brackets of the external
Duplexer and wrap the band to fit around the pole.
Figure 38 - pole mounting stainless steel bands (2 required)
3. Feed the end of the first band into the screw housing and start tightening around the pole.
Repeat this step with the second band.
4. After tightening the bands, carefully fold the excess band length back over the band’s
tightening screw to prevent accidental release, as shown below:
Figure 39 - fold back band
The following displays the Air4G and the external Duplexer mounted.
Figure 40 - Pole Mounted external Duplexer.