AS-80
Oxygen output:
80 SCF/hr at 0–45 psig*
2.10
Nm
3
/hr at 0–310 kPa**
Oxygen purity:
90% minimum
Oxygen dew point:
-73°C
-100°F
Dimensions:
20 x 16 x 60 in. (W x D x H)
51 x 41 x 152 cm (W x D x H)
Approximate weight:
338 lb
153
kg
Feed Air Requirements
Flow:
20
SCF/min*
0.53
Nm
3
/min**
Pressure:
90 psig minimum
620 kPa minimum
Temperature:
50°C
maximum
122°F
maximum
Power requirements:
120 VAC, 50 Hz, Single Phase, 60 W, 0.5 Amp
120 VAC, 60 Hz, Single Phase, 60 W, 0.5 Amp
240 VAC, 50 Hz, Single Phase, 60 W, 0.25 Amp
240 VAC, 60 Hz, Single Phase, 60 W, 0.25 Amp
*SCF (standard cubic foot) gas measured at 1 atmosphere and 70°F.
**Nm (normal cubic meters) gas measured at 1 atmosphere and 0°C.