Corporation
5-4
AS-20—1000 Instruction Manual
Model
Feed Air Inlet Connection Size
Feed Air Hose Size
AS-20,
AS-45
¼” NPT female bulkhead fitting with a ¼” NPT
male x ¼” NPSM ball-end joint adapter
¼” ID minimum
AS-80
¼” NPT female bulkhead fitting with a ¼” NPT
male x
⅜
” NPSM ball-end joint adapter
⅜
” ID minimum
AS-160,
AS-250
½” NPT female bulkhead fitting with a ½” NPT
male x ¾” NPSM ball-end joint adapter
½” ID minimum
AS-450
¾” NPT female bulkhead fitting with a ¾” NPT
male x ¾” NPSM ball-end joint adapter
¾” ID minimum
AS-750
1” NPT Female fitting next to V-2
1” ID minimum
AS-1000
1” NPT Female fitting next to V-2
1” ID minimum
Table 5-1 Feed Air Connection Sizes and Hose Sizes
2) Install your oxygen receiver. If AirSep Corporation provided your oxygen
receiver, assemble the receiver as follows (See Figure 5-2.):