9.3
Application of a pre-filter/water separator
According to the condition of the compressed air plant and the distribution network, it is
possible that unexpectedly dirt, condensate or oil also gets discharged at the measuring
point. In order to avoid damage to the measuring probe in such critical application areas, a
water separator with fine filter can also be connected before the device. The components
connected in series should not change the humidity content of air or unnecessarily worsen
the response behaviour. Suitable components can be obtained from us on enquiry.
9.4
Mounting examples
The device is suitable for a large number of application areas. With the flexible design of
measuring chamber, the device can be easily adapted for the intended application:
Connection to a quick coupling 7.2 mm NW:
This connection is fast and simple, can be done in
minutes without expensive installation.
Mounted with a plug nipple NW 7.2 mm below
with 3/8“ fitment threads.
The device can be directly plugged onto the
coupling without further fastening.
The diverting throttle is adjusted at approx. 60
l / h (factory setting during delivery).
Fixed connection over a compressed air line:
This connection is ideal with short distance to the
main line, since no flushed out air is used.
Mounted with a double nipple 3/8“ below,
other side matching with the pipe connection.
The device is directly mounted on the T-joint.
For immediate connection to a main line, the
diverting throttle is closed.
In case of larger connection length or branch
line, the throttle is adjusted to approx. 60 l / h