background image

 

 

 

    

 

 

 

 

 

 

 

                 

 

                      

 

 
 
 
 

 
 

 

RECTANGULAR

 

DUCT

 

FAN 

AIR-DKF-B

 

SERIES 

 

USER

 

MANUAL 

Summary of Contents for AIR-DKF-B 100-50

Page 1: ...RECTANGULAR DUCT FAN AIR DKF B SERIES USER MANUAL...

Page 2: ...NTY 9 PRODUCT INFORMATION 10 PRODUCT DESCRIPTION 10 A RONN AIR DKF B SERIES FAN LABEL 11 AREA OF USE 12 PACKAGE CONTENTS 12 GENERAL NOTES ABOUT THE MACHINE 13 ABBREVIATIONS 14 GENERAL SAFETY INSTRUCTI...

Page 3: ...UCTIONS 29 ELECTRICAL CONNECTION DIAGRAM 31 SINGLE PHASE MOTOR CONNECTION 31 THREE PHASE MOTOR CONNECTION 32 PRODUCT USE 33 1 MANUAL OPERATION 33 2 AUTOMATED USE 33 CARE INFORMATION 34 PERIODIC MAINTE...

Page 4: ...gure 3 AIR DKF B Series Fan Overall Dimensions 15 4 Figure 4 Warning labels on the machine 17 5 Figure 5 AIR DKF B Series Fan Connection 28 6 Figure 6 Single Phase Motor Connection 31 7 Figure 7 Three...

Page 5: ...S STEMLER SAN DI T C LTD T CENTRAL OFFICE FACTORY TATLISU MAH ENOL G NE BULVARI M RA TOWER KAT 3 D 16 ER FAL ATA EH R STANBUL KARATEPE MAH CUMHUR YET CAD MERA SOK N0 13 KARTEPE KOCAEL TEL FAX 90 216...

Page 6: ...ectrical installation low or excessive voltage damage and malfunctions that may occur if the product is used at a voltage different from the voltage on the label 4 Damages and malfunctions caused by u...

Page 7: ...he malfunction of the product is not resolved within 10 business days the manufacturer or importer company must make another product with similar features available to the consumer until the repair of...

Page 8: ...n by any of its dealer agency representative importer or manufacturer respectively The consumer may request free replacement of the product a refund or a discount on the sales price at the rate of def...

Page 9: ...ning and authorized by us The warranty is void if other persons interfere with the machine without our written agreement 3 The warranty given by our company is valid if the machine is used as describe...

Page 10: ...sed is inappropriate and unfavorable Failure to comply with or misuse the subjects specified in the manual Using electricity that is not suitable for the specified electrical installation Any modifica...

Page 11: ...ion thanks to the openable motor cover Figure 1 AIR DKF B Series Fan Fan Housing The fan housing is made of high quality galvanized steel Fan flanges are manufactured by bending from the body and thus...

Page 12: ...55 electrical connection box made of plastic material is offered as standard Accessory Speed Switch Damper Duct Impeller A RONN AIR DKF B SERIES FAN LABEL Figure 2 AIR DKF B Series Fan Label Sample BA...

Page 13: ...ended purpose The machine s operating capacity is limited to the channel dimensions on the label AIRONN cannot be held responsible for any damages that may arise from using the machine beyond the spec...

Page 14: ...the instructions given in the MAINTENANCE INFORMATION section are followed These instructions are provided as a precautionary measure against any safety risk to personnel using the machine Full capac...

Page 15: ...D K F B S E R S Page 14 ABBREVIATIONS AIR XXX X XX XX Internal dimensions of the rectangular channel cm 30 15 40 20 A 40 20 B 50 25 60 35 70 40 80 50 100 50 Fan blade structure B Backward Type of fan...

Page 16: ...0 20A 400 520 200 225 250 450 425 7 AIR DKF B 40 20B 400 520 200 225 250 450 425 7 AIR DKF B 50 25 500 590 250 275 300 550 525 9 AIR DKF B 60 35 600 740 350 375 400 650 625 9 AIR DKF B 70 40 700 830 4...

Page 17: ...3 66 8 6 AIR DKF B 40 20A 230 50 100 0 47 2580 3 58 11 5 AIR DKF B 40 20B 230 50 150 0 7 2600 4 57 11 8 AIR DKF B 50 25 230 50 200 0 9 2600 6 58 15 8 AIR DKF B 60 35 220 50 210 1 1400 8 60 43 6 AIR D...

Page 18: ...allation use maintenance and scrapping of the machine WARNING LABELS ON THE MACHINE There s an electricity Caution Rotating Machine Warning Danger of the hand getting stuck Grounding Standing Under Lo...

Page 19: ...uch a way that it is not exposed to any vibration dust corrosive or chemical substances until it reaches the place where it will be installed Do not accept products that are not in the original packag...

Page 20: ...weights in the technical specification table Products with excessive weight should be removed from the pallet with a forklift etc 3 It must be ensured that the load is correctly balanced and will not...

Page 21: ...he product is to be wall mounted mounting brackets or clamps must be used Fans are not ready for use when unpacked The product must be connected to the special ventilation duct produced in sizes suita...

Page 22: ...truction in the path of the air flow Inlet and outlet of the products should be connected to the channel Do not use the product at ambient temperatures above 40 C Fans are supplied with single phase 2...

Page 23: ...he machine is in operation personnel must not be present on the machine for any reason The machine must only be used by a trained and authorized operator The fan must not be operated when not connecte...

Page 24: ...Before any maintenance work is carried out on the machine the power must be disconnected from the main line Maintenance should be carried out after the machine has come to a complete stop to avoid lim...

Page 25: ...NCE NEVER PERFORM MAINTENANCE OR REPAIR WORK WHILE THE MACHINE IS RUNNING During routine inspection and maintenance of some parts of the machine it may be necessary to keep the machine running In this...

Page 26: ...to its components must be used in accordance with occupational safety rules Personnel must take precautions against limb entrapment during disassembly Disassembled and cut sharp edged parts must be st...

Page 27: ...Care should be taken to ensure that the products transported to the construction site or assembly area are not exposed to weather conditions during storage and that there is no excessive dust and dirt...

Page 28: ...nger of corrosion Since the water remaining between the product and the stretch film will have a corrosive effect on the product with the effect of the sun the stretch film should be removed immediate...

Page 29: ...illed in the ceiling in accordance with the frame dimensions and distances and dowels should be placed in these holes The fan should be suspended and fixed as in the picture Seal tape should be applie...

Page 30: ...tc indicated on the product must match the electrical connection information at the place of installation For safety reasons make sure that the grounding terminal on the terminal block is connected to...

Page 31: ...hat the blades rotate in the correct direction When the product is in operation make sure that there is no knocking or rubbing noise or vibration caused by the rotation of the fan or extractor fan The...

Page 32: ...www aironn com tr A I R D K F B S E R S Page 31 ELECTRICAL CONNECTION DIAGRAM SINGLE PHASE MOTOR CONNECTION Figure 6 Single Phase Motor Connection...

Page 33: ...www aironn com tr A I R D K F B S E R S Page 32 THREE PHASE MOTOR CONNECTION Figure 7 Three Phase Motor Connection...

Page 34: ...sed easily and safely with the 0 1 switch logic by connecting a pako switch or fuse between the electrical energy and the junction box connection on the product 2 AUTOMATED USE It is possible to contr...

Page 35: ...uld be seen The operator can take notes of the basic parameters at regular intervals so that the life of the machine can be properly determined However the maintenance technician should ask the operat...

Page 36: ...uld be replaced To avoid contamination or deposits on the blades and motor maintenance must be carried out taking into account the operating conditions of the product Failure to do so may shorten the...

Page 37: ...ALFUNCTIONS AND ELIMINATION ANORMAL SITUATION PROBABLE CAUSE CORRECTIVE ACTION EXCESSIVE SOUND NOISE ROTOR INSTABILITY REPLACE THE ROTOR DEVICE IS NOT WORKING MOTOR DAMAGED REPLACE THE MOTOR CONDENSER...

Page 38: ...16 erifali stanbul TEL FAX 0216 594 5696 0216 594 5717 SIGNATURE AND STAMP OF THE AUTHORIZED PERSON OF THE COMPANY SELLER COMPANY TITLE ADDRESS TEL FAX INVOICE DATE and NO SIGNATURE AND STAMP OF THE A...