3.Operation
3-18
3.4.7
Stopping
<Procedure>
1.
Close fully service valve.
2.
Set the CONTROL POWER switch [A] to
position.
3.
The engine will stop automatically after a 180 second cool down.
4.
After stopping the engine, close and lock the front panel. Store the key in a safe place.
Unless all the service valves are fully closed upon stopping operation, the compressed air will be
sent in reverse direction in the hoses (pipes) connected to air tools and relieved to atmosphere
continuously through the auto-relief valve. Further, when re-starting operation next time,
compressed air will be jetted out through air valves.
A180437
3.4.8
Air bleeding in fuel line
Should the machine stop due to fuel shortage, perform air bleeding according to the following steps.
<Procedure>
1.
Refill the fuel tank.
2.
When CONTROL POWER switch is turned to
position, electromagnet pump starts to automatically
bleed air in fuel line.
3.
Air bleeding is completed about one minute.
A180191
Fuel air-bleeding
electromagnetic pump
Sedimenter
Fuel filter
A
Fuel pre-filter
Go