AirLabs AirHavn Pro User Manual Download Page 1

 

 

 

 

 

 

www.airlabs.com    

 

©2020 AirLabs  

 

 

 

USER GUIDE 

 

User guide 

1

 

Before You Start 

2

 

Introduction to the AirHAVN PRO 

2

 

Important Safety Warnings 

3

 

Environmental 

4

 

Performance 

4

 

Installation and operation 

5

 

Components 

5

 

Installation 

6

 

Operation 

7

 

Service and maintenance Information 

10

 

Troubleshooting 

19

 

Warranty Information 

21

 

Return and Warranty Policy 

21

 

Technical Specifications 

23

 

Legal 

23

 

Simplified EU Declaration of Conformity 

23

 

 

 

 

Summary of Contents for AirHavn Pro

Page 1: ...tant Safety Warnings 3 Environmental 4 Performance 4 Installation and operation 5 Components 5 Installation 6 Operation 7 Service and maintenance Information 10 Troubleshooting 19 Warranty Information...

Page 2: ...can include pollen mould spores soot dander and can vary in size from PM10 10 m and PM2 5 2 5 m down to particles below 0 1 m in diameter It removes the smallest nanoparticles thought to be the greate...

Page 3: ...se the unit for a longer period of time Do not expose the unit to nearby objects that radiate heat to avoid damage to the unit Do not place the unit in moist and humid environments specifically do not...

Page 4: ...omponents which can be recycled and reused The crossed out wheelie bin symbol on the product literature or packaging reminds you that all electrical and electronic products must be taken to separate c...

Page 5: ...5 www airlabs com 2020 AirLabs INSTALLATION AND OPERATION COMPONENTS The following contents are included in the box 1 AirHavn Pro main unit and filters 2 Mains power cable and plug 3 User Guide...

Page 6: ...is drawn into the front of the AirHavn Pro and through the filter system Clean air is delivered into and around the room from the two outlet vents on the sides of the unit and from the outlet vent on...

Page 7: ...he speed setting showing 0 To switch the AirHavn Pro off just unplug it The AirHavn Pro uses very little power while in Standby mode but we still recommend unplugging it when not in use to save energy...

Page 8: ...ll the indicator lights on the control panel If any lights do not illuminate please review the troubleshooting section The ON OFF FILTER button is for activating deactivating the Electrostatic Precipi...

Page 9: ...Status The filtering status for the electrostatic precipitator filter is indicated by the three LED lights within the panel If the filter is switched off using the ON OFF FILTER button on the control...

Page 10: ...pened before the power is disconnected at the mains plug The microswitch must not be modified for any reason and must not be used in the closed position in any way so as to compromise safety If the mi...

Page 11: ...Precipitator ESP Filter The filter works by using a high voltage power source to apply an electrical charge to any particles within the airflow and then trap those charged particles on collection pla...

Page 12: ...er Maintenance To carry out maintenance of the filter systems it is necessary to remove all the filter units from the main body of the AirHavn Pro When removing the filter systems from the unit the us...

Page 13: ...the removed contaminant b Stage 2 tray used for neutralising any residual washing detergent 2 Non corrosive detergent for washing the ESP filter See www airlabs com for a list of suitable cleaning de...

Page 14: ...om the unit and proceed to clean the filter as follows 1 Immerse the filter cell in the stage 1 tray with the detergent and soak until the dirt is dissolved 2 Remove the electrostatic cell and rinse t...

Page 15: ...hanical strength Use a cotton flock and methylated spirits to remove any residual traces of dirt 6 Ensure that the cell is thoroughly clean and dry before reinstalling it Metal Pre Filter Cleaning Rem...

Page 16: ...as the ESP filter is cleaned The ENC filter is located behind the ESP filter and is removed from the unit by sliding out the metal holding frame The filter retaining bars can be removed to provide ac...

Page 17: ...rlabs com website Ceramic insulators Material deposits and dirt Repeat the washing process until clean Broken insulator or sign of crack Insulators must be replaced Please contact support via the www...

Page 18: ...ices that automatically disconnects the high voltage power supply if a malfunction is detected There is a thermal fuse inside the unit that will cut the power supply if a short circuit occurs within t...

Page 19: ...t automatically The Alarm is activated Power off the unit at the wall and power on again If the problem persists please contact support via the www airlabs com website The AirHavn Pro fan stops runnin...

Page 20: ...ies trapped between the collection plates The particles deposited on the plates must be removed See service information red LED on MAINTENANCE ESP filter must be cleaned Filter will be switched off Ca...

Page 21: ...will be required for the RMA Model number and serial number of the failed unit Full description of Apparent Damage or Failure Component description if claiming for a specific component rather than th...

Page 22: ...22 www airlabs com 2020 AirLabs The label provides the identification and technical data of the unit...

Page 23: ...68 x 303mm Weight 30kg LEGAL SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby AirLabs Limited declares that this product is in compliance with Directives 2006 42 EC 2004 108 EC and 2006 95 EC The full t...