ON/OFF – Plug in to a standard (120V AC) electrical outlet. The LED Display will turn on for 2 sec-
onds then turn OFF. Press the ON/OFF button once and the “Operating” indicator will turn ON. Mist
may not appear immediately; allow up to 15 minutes for the water in the tanks to transfer to the base.
Mist Output – When you turn the unit ON, it will default to the lowest mist setting. Pressing the “Mist” but-
ton will increase the output. Press once for Medium, twice for High, three times for Supreme, four times for
the Turbo Setting. Pressing the Mist button a fifth time will bring the unit back to Low. NOTE: Turbo setting
is intended for those wanting a more powerful mist and works best while the Extension Nozzle is be-
ing used. The Turbo setting will operate for 40 minutes and will then go to the Supreme Mist Setting.
User must wait 20 minutes before Turbo setting can be used again.
1
6
7
5
4
8
2
3
5
Operating Instructions
WARNING: DO NOT operate the humidifier without water in at least one of the tanks.
WARNING: NEVER lift the tanks OFF the Base while the unit is operating.
The Delay Start and Auto-Off buttons allow you to set the humidifier to turn ON and OFF automatically
as desired.
Delay Start – The Delay Start feature allows you to program the unit to turn ON automatically. To use,
press the “Delay Start” button once; you will see “Delay Start” 01:00H illuminated on the display. This
feature works in 1 hour increments and is programmable up to 24 hours. Simply keep pressing the
Delay Start button until you get to your desired delay start time, once you have reached the time the
display will flash three times and then will start to
countdown until the unit turns ON.
Auto-Off – The Auto-Off feature allows you to run the
humidifier now and set it to turn OFF at a specific time
automatically (in 1 hour increments from 1-24 hours).
To use - press the “Auto-Off’ button once; you will see
“Auto-Off” 01:00H illuminated on the display. This feature
works in 1 hour increments and is programmable up to
24 hours. Simply keep pressing the Auto-Off button until
you get to your desired Auto-Off time, once you have reached
the time the display will flash three times and then start to
count down until the unit turns OFF. The display will start
alternatingbetween the current ambient humidity and the
Auto-Off Timer. NOTE: You can use the Delay Start and Auto-Off functions together on this fully
programmable LED Display to program the humidifier to turn ON and turn OFF at your desired times.
Humidistat – By using this feature the humidifier will automatically monitor and
control the humidity level according to your desired setting. Once the desired humidity level is reached
the mist will shut OFF until the humidity drops below the setting and then the mist will turn back ON
automatically to maintain the humidity level desired. To set this feature press the “Humidistat” button
to your desired setting. Settings range from 40%-95% RH (Relative Humidity) in 5% RH increments.
A 40%-60% Relative Humidity is recommended. Once you set your desired humidity, the number will
flash three times and then the display will revert back to the Relative Humidity. To view the set humid-
ity level, press the Humidistat button once.
Beep/Dim – The humidifier automatically defaults to an audible beep when changing settings, the
waterless indicator will illuminate and you will hear three beeps when the humidifier is out of water and
the LED Display will be illuminated.To disable one or more of these settings, follow the steps below:
Press Beep/Dim once to disable all sound (Beep Off will flash on the display three times and then will
remain on the display to indicate the sound is OFF). Press the button twice to turn the LED Display OFF
(sound will remain OFF) and press a third time to enable the LED Display and the sound (default function).
LOW Water – When the tanks are out of water the “waterless” indicator will appear in the display,
you will hear three beeps and the automatic safety shut-off will turn the Ultrasonic Nebulizer & unit
OFF. Note: You can disable the audible beep by pressing the Beep/Dim button once. To re-enable, press the
Beep/Dim button two more times.
Extension Nozzle – To convert this unit from a Tabletop unit to Floor unit simply remove the Dual
Directional Mist Nozzle from the top of the Left Water Tank. Place the unit on your desired floor area
and insert the Extension Nozzle into the Top of the Left Water Tank. Then place the Dual Directional
Nozzle on the top of the Extension Nozzle.
WARNING: Be sure the unit is unplugged and
turned OFF when changing the Nozzles.
Remote Control –
Be sure to remove the clear
pull tab before using the
remote.
The functions on the Remote
Control mirror those on the
humidifier from Low to Supreme.
When using the Remote Control,
you can control the humidifier
from your desired location.
NOTE:
The Turbo function cannot
be controlled by the Remote. In
order to operate the Turbo setting
it must be controlled manually
on the unit.
Extra Features
Safety Shut Off
Automatic Use
Manual Use