background image

© Airflow

 

-

 we reserve the right to make changes without prior notice

Uno hab

 PSF

 Switching 

P

ower 

S

upply

-

F

lush

Installation and Operating Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

1.0 Important information

In order to ensure complete and effective 

operation and for your own safety, all of the 

following instructions should be read carefully 

and observed.

This document should be regarded as part 

of the product and as such should be kept 

accessible and durable to ensure the safe 

operation of the fan. All 

product

-related 

safety regulations must be observed.

These installation instructions cannot 

take all 

i

nstallation, operating and 

maintenance conditions into account. You 

can obtain further information from your local 

dealer or the product data sheet, which can 

be downloaded on the internet.

1.1 SAFETY INSTRUCTIONS

Special regulations apply for use, 

connection and operation; consultation 

is required in case of doubt. Further 

information can be found in the relevant 

standards and legal texts.

m

 

The following points must be 

observed before any cleaning, 

maintenance and installation work:

•  Isolate device from the mains power

supply and secure against being

switched on again!

•  After switching off, a waiting time

of 5 min. must be observed, as

dangerous voltages may be present

after disconnection from the mains due

to internal capacitors!

• Non-observance, touching live electrical 

parts or improper use of this power

supply unit can result in death, serious

injuries or significant material damage.

• All p

roduct

-related safety reg

.

 must

 

be

observed!  Further  country-specific

regulations must also be observed.

1.2 Application

This compact, fully encapsulated switching 

power supply is solely designed as a 

decentral power supply for the 

Uno hab

 unit for 

installation 

in a flush-mounted box.

Further information can be found in section 3.0 

“Installation”.

– Normal use:

The 

Uno  hab

 PSF power supply unit is only

approved for fixed installation inside buildings in

a flush-mounted box. The maximum permissible

ambient temperature can be found on the type

plate.

– Reasonably foreseeable misuse:

The power supply unit is not suitable for

operation  under  difficult  conditions,  such  as

high levels of humidity, aggressive media,

long standstill periods, heavy contamination,

excessive loads due to climatic, technical or

electronic influences. The same applies for the

mobile use of fans (vehicles, aircraft, ships,

etc.). Usage under these conditions is only

possible with approval from Airflow, as

 

the

standard version is not suitable in this case.

– Improper, prohibited use:

Any use other than the intended use is not

permitted! The conveying of solid matter or

solid matter content > 10µm in air and liquid is

not permitted!

1.4 Personnel qualification

DANGER!

The electrical connection and start-up must only 

be carried out by qualified electricians.

 

Installation, servicing and maintenance of the 

fan  must  only  be  carried  out  by  qualified 

electricians. 

Uno hab

 individual room ventilation 

units can be used by children over the age of 

8 as well as persons with physical, sensory, 

or mental disabilities or lack of experience 

and knowledge, if they are supervised or 

instructed with regard to the safe use of the 

unit and they understand the resulting risks. 

Children must not play with the unit. Cleaning 

or user maintenance must not be carried out by 

unsupervised children.

1.4 Scope of delivery

The delivery includes the switching power supply

 

Uno hab

 PSF / Part Number: 90000996

2.0 Warranty claims – exclusion of liability

 

If the following instructions are not observed, our 

warranty shall be invalidated. The same applies 

to  liability  claims  against  Airflow. T

h

e use of

 

 

accessory parts, which are not recommended 

or  offered  by  Airflow, is not permitted. Any 

possible damages are not covered by the 

warranty.

2.1 Certificates - guidelines

If the product is installed correctly and used to its 

intended purpose, it conforms to all applicable 

EU guidelines at its date of manufacture.

2.2 Shipping

The power supply unit is packed ex

-

works 

in such a way that it is protected against 

normal transport strain. Carry out the shipping 

carefully. It is recommended to leave the power 

supply unit in the original packaging

 until 

required

.

2.3 Receipt

The shipment must be checked for damage and 

correctness immediately upon delivery. If there 

is any damage, promptly report the damage 

with the assistance of the transport company.

 

If complaints are not made within the agreed 

period, any claims could be lost.

3.0 Installation

-  During operation, the power supply unit must

not be accessible.

-

 A  suitable  flameproof  casing  must  be

provided in the end product.

-

Sufficient cooling must be ensured.

-  The maximum surface temperature must not

be exceeded.

The casing fulfils the requirements of IP 67 and 

it is fully protected against dust and penetrating 

humidity.

The power supply units are intended for 

installation  in  deep  (61  mm)  flush-mounted 

boxes  with  a  68  mm  diameter  (fire  resistance 

850°C according to VDE 0606).

The connection can be made via the connecting 

wires with suitable terminals.

Connecting cables:

Input side: 

 0.8 mm² (black - white) with outer 

sheath, wire end ferrule

Output side:  0.52 mm² (black - red) tin-plated

3.1 Electrical connection / start-up

m

DANGER

Touching live parts will result in electric 

shock. Only connect with no voltage 

present!

–  The electrical connection and initial start-up

are to be carried out in accordance with the

relevant wiring diagrams and are only to be

carried out by a certified electrician.

–  The relevant standards, safety

regulations

 

(e.g.  DIN  VDE  0100,  EN

50178),  as  well

 

as the technical

connection conditions of

 

energy suppliers

are to be adhered to!

–  A multipole mains section switch/isolator, with

a minimum contact opening of 3 mm (VDE

0700 T1 7.12.2 / EN 60335-1) is mandatory!

–  The power supply and the supply network

must be sufficiently fused.

– The network connection must comply with

IEC 62103, EN 50178 and IEC 60364, VDE

100

 Network configuration, voltage and frequency

must be consistent with the rating plate

information.

– The supply 

cable

 must be introduced, so

that

 

no water can get in along the cable in

case of

 

water exposure.

–  Never work on the power supply unit when it is 

live! There is a risk of electric arcs and electric 

shock which can result in death, serious

injuries or significant material damage.

Warning:

Dangerous voltages and components with 

significant amounts of stored energy may 

be present during normal power supply unit 

operating conditions. However, they are not 

accessible.

Improper use can result in electrical shock 

or  significant burns! Keep away from fire 

and water!

The power supply unit must be connected 

according to wiring diagram S

D-3

 (1 power 

supply unit), or S

D-4

 (2 parallel power 

supply units) depending on the configuration.

Attention!

A ferrite is mounted on the output side of 

the power supply unit. This is a component 

of the power supply unit and it is required 

to ensure correct functionality. The ferrite 

must not be removed.

The input and output cables must be installed 

so that they are clearly separated from one 

another (see Fig. 1). Ideally, position the ferrite 

at a distance of approximately 1 cm behind the 

power supply unit. Install the cables without 

twisting. The cables must not cross each other 

and must be shortened accordingly.

All wiring terminals must comply with DIN EN 

60998.  These  terminals  must  be  designed  for 

a temperature range from 85 °C and a voltage 

of 300 V.

Terminal recommendation: Wago Type 221

Fig.1