background image

All  electrical  installation  must  be  carried  out  by  an   
approved  electrician  in  accordance  with  Part  “P”  U.K. 
Building  Regulations  and  to  the  latest  IET  standards,  or 
the appropriate regulations in the country of installation.

 

The  iCONsmart  15  requires  a  110V

240V  50/60  Hz 

supply. 

 

The iCONsmart is IPX5 rated and therefore it is suitable 
for mounting in bathrooms (in Zone 1 and 2).

 

For  fans  mounted  in  Zones  1  &  2  as  defined  in  BS 
7671:2018, additional protection must be provided by an  
RCD  not  exceeding  30mA  as  well    recommends  having 
an AFDD.

 

Smart Fan Installation 
and Operation Guide

 

iCONsmart 15 

-

 72687221

 

Fan Overview

 

Main Body

 

IPX Cover

 

Front Cover

 

Model

 

A

 

B

 

C

 

D

 

E

 

iCONsmart 15

 

194

 

118

 

100

 

72

 

144

 

 

Bluetooth connection 
to smart device

 

 

Set flow rates

 

 

Change room name

 

 

15 minute overrun

 

These  include:  Timer  Module  (TM)  functionality 
that  can  be  unlocked  via  a  code  (on  a  scratch 
card), Humidity Timer (HT), Motion Sensor Timer 
(MST)  or  a  combination  of  all  three  (MSHT). 
These  modules are available separately and can 
be fitted at the time of installation or retro

-

fitted.

 

(MST)

 

Front

 

Side

 

(HT)

 

60000316

Issue 1 05/19

 

1.

 

Ensure  selected  power  source  being  used  is 
isolated.

 

2.

 

Front  cover  iris  leaves  must  be  in  the  fully 
closed position.

 

3.

 

Remove  fixing  screw  from  bottom  of 

front 

cover. 

(Fig.4)

 

4.

 

Hold  main  body,  turn  the  front  cover        
anticlockwise  .  Note  front  cover  position  for  
re

-

assembly purposes. Lift cover off.   

(Fig.1/4)

 

5.

 

Undo  the  locking  screw  in  the  middle  of  the 
IPX cover. Lift IPX cover off. 

(Fig. 5)

 

Screw position

 

Locking screw 

 

(If  you  have  purchased  a  module,  refer  to  module 
instructions now.)

 

6.

 

Fix  sealing  grommet  supplied  into  the  cable 
entry hole. 

(Fig. 6)

 

7.

 

Pierce grommet to allow the mains cable to be 
fed through whilst maintaining seal integrity.

 

8.

 

Offer up supply cable to fan. Cut to length needed

.

 

9.

 

Position  fan  so  cable  entry  and  fixing  holes  align 
with  those  on  mounting  surface.  Feed  through 
cable and fix fan. 

(Fig. 6)

 

10.

 

Wire  fan  to  supply  cable,  referring  to  electrical    
installation guide. 

(Page 5)

 

11.

 

Using  cable  clamp  provided,  secure  mains  cable 
into place.

 

12.

 

To  replace  IPX  cover.  Line  up  the  L  and  R  
symbols on the main body of the fan 

(Fig. 6)

 with 

the  L  and  R  symbols  on  the  IPX  cover, 

(Fig .7).

 

Lightly press IPX cover onto main body.

 

13.

 

Refit the locking screw, checking the IPX cover 
is  secure.

 

Cable Entry 

Hole

 

Mains Terminal

 

Fixing Holes

 

Cable Clamp

 

14.

 

Position  front  cover  over  IPX  cover  in  same 
orientation  as  it  was  removed.  Lightly  press 
front  cover  onto  fan  and  rotate  clockwise  up 
to stop. Refit fixing screw. 

(Fig. 8)

 

iCONsmart 

comes 

with 

flow 

sensing         

technology  to  automatically  overcome  duct  
system pressures.

 

 Prepare Wall or Ceiling

 

The  iCONsmart  can  be  installed  into  a  wall  or 
ceiling.

 

When  recessing  fans  in  the  ceiling,  a  plywood 
support  (min  18mm  thick)  should  be  mounted 
between  the  ceiling  joists.  Fans  should  not  be 
fitted  to  unsupported  plasterboard. 

(See  Fig.  3, 

Page 4)

 

1.

 

Mark out and drill a spigot hole to suit 100mm 
diameter rigid ducting.

 

2.

 

Make  provision  for  the  electric  supply  cable 
and  wall  plugs  /  appropriate fittings  using the 
main  body  as  a template.  Level  using  guides 
below the L and R symbols. 

(see Fig. 6, page 7)

 

3.

 

Fit  the  wall  plugs  provided  or  fixings  as         
appropriate for the surface.

 

Page 2 of 16 

Page 7 of 16 

Page 8 of 16 

Page 4 of 16 

Page 5 of 16 

Page 6 of 16 

Electrical Installation

 

Fig. 1 

Fig. 2 

Back

 

Module Controls

 

iCONsmart  has  several  features  included  as 
standard, and can also be fitted with digital micro 
modules to give a range of extra control options. 

 

Standard Features

 

 

Commission / Notify 
NICEIC of install

 

 

Keep 3 month rolling 
log of fan switch

-

on 

time and power usage

 

 

Flow rate sensor

 

Page 3 of 16 

Fig. 3 

Installation

 

Fig. 4 

Fig. 5 

Fig. 6 

Screw

 

L and R Symbols

 

L Symbol

 

R Symbol

 

Fig. 7 

Fig. 8 

Switch Live Wiring 

Basic Wiring 

(TM)

 

ØA

 

B

 

D

 

Ø

C

 

E

 

Important:  Switches  for  fans  should  be  selected  and 
sited in accordance with BS 7671:2018.

 

Reviews: