Airflow ecoDRY 550 Series Installation And Operating Manual Download Page 4

 

 

Page 4 of 6 

 

 

 
5. Maintenance 

Warning

 

– 

before commencing any maintenance on this product, please isolate the 

appliance from the power supply. 

Clean the hand dryer using a soft cloth dampened with water and detergent. To ensure the correct 
functioning of the product, periodically check that the inlet grille and air outlet mechanism are clear 
of dust and debris. 
 
The 

HEPA filter

 which is located inside the unit ensures air is kept free from dust and dirt. The filter 

should be cleaned every 6 months or so by using a jet of compressed air/ vacuum cleaner (from a 
distance of 20cm). Do not immerse/ clean with water as these filters are made from HEPA filter  
paper. By using this quality H13 HEPA filter and with regular maintenance and replacement when 
required, you can be assured of 99.99% bacteria free air from the dryer. The filter should be 
replaced after 1,000 hours of use in conjunction with the carbon brushes (see next section). 

Filters 

are not covered under the warranty. 
 

Replacement of the filter

 

Remove the cover as described in the section on front cover removal (Figure 2). 

Remember to 

isolate from the power supply before commencing the cleaning or replacement of the filter

The filter simply slides out as shown in Figure 4 

– clean/ replace depending on the requirement. 

 

 
 
 
 
 
 
 
 
 
 

 
The plastic parts inside the hand dryer are treated with 

Agion Silver Antimicrobial

 which reduces 

bacterial build on the dryer surfaces by 99.9%. The above measures give the ecodry 550 Hand 
Dryers double antibacterial protection levels making it an ultra-hygienic drying system. 
 
The 

Carbon Brushes 

on the drive unit of the motor have a life span of 1,000 hours. The duration 

varies depending on the conditions of use, whether the filters have been cleaned on a regular basis 
and general maintenance of the appliance. Please contact your installer for replacement of these 
carbon brushes 

– 

these brushes are not covered by our warranty

 and should be ordered from 

Airflow as a consumable part. It is a simple replacement procedure as the carbon brushes are 
supplied in twin cartridges which fit onto each side of the drive unit. Indication that the brushes are 
worn and need replacing will be the hand dryer starts to work intermittently or even fails to start. 

Figure 4 

Summary of Contents for ecoDRY 550 Series

Page 1: ...et blade wall of air Revolutionary double level antibacterial protection system Smallest high speed hand dryer in it s category Contemporary Design Ergonomic features Manufactured from recycled materials Read before commencing installation Please leave these instructions with the person responsible for the premises ecoDRY 550 ABS Part 90000242 ecoDRY 550 Satin Part 90000243 ...

Page 2: ...iple dryers are being installed alongside each other allow enough space for people to access the dryer Also if installing next to an adjoining wall the dryer should be positioned at least 200mm from this wall to allow for proper access Fix the hand dryer to the wall with the fixing kit provided using the enclosed template to mark out where the holes should be drilled You should ensure that the ele...

Page 3: ...these instructions the ecoDRY range of hand dryers are completely safe The materials used do not constitute a hazard All ABS parts are made from flame retardant materials Wiring For hard wiring into a wall in a washroom 4 Operation The hand dryer automatically starts up when it senses the hands approaching the air outlet mechanism and stops when the hands move away The unit has no heating element ...

Page 4: ...described in the section on front cover removal Figure 2 Remember to isolate from the power supply before commencing the cleaning or replacement of the filter The filter simply slides out as shown in Figure 4 clean replace depending on the requirement The plastic parts inside the hand dryer are treated with Agion Silver Antimicrobial which reduces bacterial build on the dryer surfaces by 99 9 The ...

Page 5: ... the elements such as rain sun etc Do not make any changes to the device Do not obstruct the air outlet point or air inlet grille Do not insert any object into the air outlet or air inlet grille In case of failure malfunction disconnect from the power supply and call your installer 6 Troubleshooting 1 The dryer blows cold air the dryer will warm up after use as the heat is generated from the opera...

Page 6: ...n of this if required The warranty does not cover the replacement of the HEPA filter or the carbon brushes both of which need to be replaced after 1 000 hours of operation These can be ordered from Airflow as spare parts as and when required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that...

Reviews: