1. Overview 

ecoDRY 550 Hand Dryers are available in two finishes; White ABS Plastic and Satin Die Cast 
Aluminium.  
 
Technical Data of these hand dryers is as follows: 
 
Supply Voltage 

– 220-240V 

Frequency 

– 50-60Hz 

Absorption (power) total 

– 550 Watts 

Protection Level 

– IP23 

Electrical Insulation 

– Class II 

Airflow Performance 

– 150m

³

/hr / 2,500l/min 

Dimensions 

– (H) 285mm x (W) 221mm x (D) 157mm 

Weight 

– 3Kg (ABS) 5Kg (Metal) 

 

2. Mechanical Installation  

The ecoDRY hand dryer should be installed at a minimum height of 120cm (from the ground to the 
air outlet/ bottom of the dryer). The hand dryer should be positioned at least 60cm from a bathtub, 
shower or hand basin. Where multiple dryers are being installed alongside each other, allow enough 
space for people to access the dryer. Also, if installing next to an adjoining wall, the dryer should be 
positioned at least 200mm from this wall to allow for proper access.

 

Fix the hand dryer to the wall with the fixing kit provided using the enclosed template to mark out 
where the holes should be drilled. You should ensure that the electrical supply (tension) does not 
exceed the maximum power of the apparatus (220 -240V). This product is intended for installation 
by a suitably qualified person. 

 
Dimensions 

 

 

 

 

 

 

Front Cover Removal 

Before installation can commence you need to remove the front cover by unscrewing the two 
screws at the bottom of the cover (see Figure 2). When the hand dryer is fixed to the wall, the cover 
should be replaced and the two screws tightened accordingly. 

 

 

 

 
.

  

 
 

 

Figure 2

 

Figure 1

 

Summary of Contents for ecoDRY 550 Series

Page 1: ...et blade wall of air Revolutionary double level antibacterial protection system Smallest high speed hand dryer in it s category Contemporary Design Ergonomic features Manufactured from recycled materials Read before commencing installation Please leave these instructions with the person responsible for the premises ecoDRY 550 ABS Part 90000242 ecoDRY 550 Satin Part 90000243 ...

Page 2: ...iple dryers are being installed alongside each other allow enough space for people to access the dryer Also if installing next to an adjoining wall the dryer should be positioned at least 200mm from this wall to allow for proper access Fix the hand dryer to the wall with the fixing kit provided using the enclosed template to mark out where the holes should be drilled You should ensure that the ele...

Page 3: ...these instructions the ecoDRY range of hand dryers are completely safe The materials used do not constitute a hazard All ABS parts are made from flame retardant materials Wiring For hard wiring into a wall in a washroom 4 Operation The hand dryer automatically starts up when it senses the hands approaching the air outlet mechanism and stops when the hands move away The unit has no heating element ...

Page 4: ...described in the section on front cover removal Figure 2 Remember to isolate from the power supply before commencing the cleaning or replacement of the filter The filter simply slides out as shown in Figure 4 clean replace depending on the requirement The plastic parts inside the hand dryer are treated with Agion Silver Antimicrobial which reduces bacterial build on the dryer surfaces by 99 9 The ...

Page 5: ... the elements such as rain sun etc Do not make any changes to the device Do not obstruct the air outlet point or air inlet grille Do not insert any object into the air outlet or air inlet grille In case of failure malfunction disconnect from the power supply and call your installer 6 Troubleshooting 1 The dryer blows cold air the dryer will warm up after use as the heat is generated from the opera...

Page 6: ...n of this if required The warranty does not cover the replacement of the HEPA filter or the carbon brushes both of which need to be replaced after 1 000 hours of operation These can be ordered from Airflow as spare parts as and when required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that...

Reviews: